User's Manual

Installation
Your Electro-Sealer can be mounted on a table or stand of your choice, either by
bolting through the same holes as used to attach the shipping base, or be attaching
the shipping base itself to the table.
A MINIMUM OF 80 PSI OF AIR is required to operate the machine. This should be
attached to the 1/4 NPT inlet of the air filter at the rear of the machine cabinet. The
air gauge at the rear of the cabinet should show 80 PSI; if not, the line pressure is not
correct.
The vacuum pump with which your Electro-Sealer is equipped is shipped in a
separate container, complete with hose and fitting. Attach and tighten the hose to its
fitting, which is located under the rear corner of the machine cabinet. The pump is
turned on by a switch located on its power cord.
Model number, serial number, and ELECTRICAL REQUIREMENTS are listed on a
plate attached to the side of the cabinet at the rear.
Prior to shipment, the machine has been completely checked out in actual operation,
including an accurate mechanical leveling of the base in relation to the electrodes.
Heat, dwell time, and pressure are the basic fundamentals that determine the results
obtainable on a thermo-plastic sealing application, such as Electro-Seal labeling. It
is impossible with the variety of fabric materials and constructions, as well as design
of garments, to establish any one setting that will give the most desirable results
under all circumstances, but settings will be suggested upon request and submission
of an application description.
4 Installation Users Manual Electro-Sealer 7112 BR