User manual

Users Manual Model 545™ Control Panel Operation 47
CHANGE CUT POS I T I ON
VALUE : ±XX NEW VALUE : ±YY
This screen follows the "PRINT OFFSET STATION 2" screen. This screen allows
the cut position to be adjusted on sense mark formats. The <YES / NO> buttons are
used to change the new cut value. The value is displayed in a positive / negative
format. The value ranges for XX and YY can be from a -10 to a +10. Pressing
ENTER will change the VALUE to the NEW VALUE. On sense mark format a
more positive number will move the cut to the right while a more negative number
will move the cut to the left.
Pressing the MODE / Down Arrow key will take the user to the "STATION 2 DOT
SHIFT" screen. Pressing the EXIT / Up Arrow key will take the user back to the
"HOME" screen.
STAT ION 2 DOT SH I FT
VALUE : ±XX NEW VALUE : ±YY
This screen follows the "CHANGE CUT POSITION" screen. This screen allows the
print position of station 2 to be adjusted in the web direction.
The <YES / NO> buttons are used to change the new dot shift value. The value is
displayed in a positive / negative format. The value ranges for XX and YY can be
from a -16 to a +16. Pressing ENTER will change the VALUE to the NEW
VALUE. A more positive number will move the print of station 2 to the front of the
machine while a more negative number will it to the back of the machine.
Pressing the MODE / Down Arrow key will take the user back to the "PRINT
CHECKOUT FORMAT" screen. Pressing the EXIT / Up Arrow key will take the
user back to the "HOME" screen.
PRINTHEAD CLEANING PROCEDURES
PRESS ENTER FOR
PR I NTHEAD CLEAN I NG PROC .
This screen follows the "PRINT / CUT POSITIONS" screen.
Pressing ENTER will take the user to the "PRINTHEAD CLEANING
PROCEDURES" screens. Pressing the MODE / Down Arrow key will take the user
to the "CALIBRATING SENSORS" screen. Pressing the EXIT / Up Arrow key will
take the user back to the "HOME" screen.
PRESS ENTER FOR
CLEAN I NG STAT I ON 1
This screen is the first screen under "PRINTHEAD CLEANING PROC." screen.
This screen allows the user to initiate a cleaning cycle for station 1. Pressing
ENTER will initiate a cleaning procedure on station 1 based on it’s default cleaning
level setting.
Pressing the MODE / Down Arrow key will take the user to the "CLEANING
STATION 2" screen. Pressing the EXIT / Up Arrow key will take the user back to
the "HOME" screen.