User manual

68 Electrical Trouble Shooting Users Manual Model 545™
Problem Probable Cause Corrective Action
Front panel does not complete
diagnostics test 2.
1) One or more PC board(s)
unplugged from the Mother
Board.
1) Power off and remove the power cord from the
AC entry. Remove the back cover and reseat
the offending board.
2) PCMCIA cartridge not inserted
correctly in PCMCIA slot.
1) Insert a PCMCIA cartridge with the arrow up
and towards the front of the printer so that the
ejector button pops out.
Printer does not receive
batches.
1) Serial communications cable
loose or unconnected.
1) Check and secure both ends of the serial cable
with the thumbscrews.
2) Printer not powered on or has
not completed diagnostics tests.
1) Power printer on and wait until front panel
displays "Ready for batches". Re-download
data.
3) Data sent to wrong printer. 1) In PcMate change to the printer that the data is
intended to be sent.
4) Configuration incorrect in
PcMate.
1) Reconfigure PcMate for Paxar PCL printer as
per your PcMate manual.
5) Batch Que data flow interrupted. 1) Purge all batches in batch Que. power cycle the
printer and re-download.
6) Faulty Thermal Control Board. 1) Replace Thermal Control Board.
7) Jumpers not configured
correctly.
1) Contact Paxar Service.