Maintenance Guide

Cobham Wireless
idDAS Installation and Maintenance Guide 00109GU Rev. 2.0
Page | 2
idDAS for Public Safety 1.1.2
idDAS supports families of products specifically designed for to meet rigid public safety requirements as
required in various regions.
idDAS public safety for North America (US and Canada) products meet the requirements as follows:
x The enclosures are painted a Fire Life Safety Red
x Compliance to NEMA4
x Support for dry contact alarms in accordance with UL 2524 ‘Standard for In-building 2-Way Emergency
Radio Communication Enhancement Systems’ sections 12 & 33, in line with NFPA 72 ‘National Fire Alarm
and Signalling Code’
x Compliance to Multiple Public Safety Standard –APCO P25 phase 1 and 2, TETRA, TETRAPOL, SMR,
ESMR, LTE
x Support for custom redundancy options
idDAS public safety for EU/EMEA products meet the requirements as follows:
x The enclosures are painted a Fire Life Safety Red
x Meet the requirements of IP66
x Compliance to Multiple Public Safety Standard TETRA, TETRAPOL, LTE
x Support for custom redundancy options
Figure 1-1 illustrates a PS NFPA idRU identified by the red enclosure. Refer to Section 8.2.1.4 for part
numbers.
Figure 1-1. PS NFPA idRU Front Panel Example