To install the SFP+ module in the MSDH
NOTE: The SFP modules are installed in
opposing directions
in the MSDH CPRI slots top row and in the
bottom row.
1
. To insert the SFP+ modules in the MSDH CPRI
top
row:
x Align the SFP+ module with the MSDH slot
opening – SFP+ label facing UP.
x
Gently insert the SFP+ until it clicks into place.
2
. To insert the SFP+ modules in the MSDH CPRI
bottom
row:
x Align the SFP+ module with the MSDH slot
opening – SFP+ label facing DOWN.
x Gently insert the SFP+ until it clic
ks into place.
MSDH to MTDI Connections 4.4.2
To connect the MSDH to the MTDI
Connect either the MTDI SM (L1 port) or the MM (L2 port) port to the corresponding SFP + module
installed in one of the MSDH CPRI port:
x L1 SFP = Multimode SFP+ transceiver 850nm 400m 10Gb MM LC
x L2 SFP = Single Mode SFP+ transceiver 1310nm 10 km 10Gb SM LC
Recommendation for connections -
For more orderly connections and intuitive identification, it is recommended to connect the lower CPRI ports
(i.e. CPRI Ports 1, 2, 3 etc.) to MTDI units or to an additional MSDH unit if relevant. The higher or remaining
CPRI ports can then be connected to remote units.
Figure 4-7. Example of MSDH to MTDI Connections
Cobham Wireless SFP+
Install in MSDH BOTTOM CPRI row
(Label facing DOWN)
Cobham Wireless SFP+ in MSDH
TOP CPRI row (Label facing UP)