Maintenance Guide

Cobham Wireless
idDAS Installation and Maintenance Guide 00109GU Rev. 2.0
Page | 67
5.4 Brackets and Fan-Hood Assembly
Depending on the model and the cooling requirements, repeaters are either provided with standard
brackets, or with a fan-hood and the relevant accessories and brackets designed for the fan-hood.
This section provides the following information:
x Standard bracket assembly for rack and wall mount installations
x Fan-hood assembly – for repeaters that include fan-hood.
NOTE: In addition to the mounting brackets or fan-hood assembly, it is recommended to use fixings as
described in section 5.5.2.3 in order to further secure the mount.
idRU No Fan-hood Brackets Assembly 5.4.1
This section is relevant for repeaters without a fan-hood.
The provided brackets are used for both wall
mount and for a rack mount procedure, where the bracket position differs according to the type of
installation.
NOTE: The installation requires x4M8 washers – not supplied with the repeater.
To assemble the brackets
1. Position the brackets according to the type of installation:
x For Rack mount – refer to Figure 5-4.
x For Wall mount – refer to Figure 5-5.
2. Use the x4 (provided) M8 x16 Screws and X4 Spring Washers (not provided) to assemble the
brackets.
Figure 5-4: Rack-mount bracket position
Figure 5-5. Wall Mount Bracket Position