MSDS

Material Safety Data Sheet
PC CONCRETE EPOXY, PART A MSDS No. 130315-37
Date of Preparation: 3-15-2013 Revision:3
Section 1 - Chemical Product and Company Identification
Product/Chemical Name: PC Concrete Epoxy, part A
Chemical Formula: Mixture
CAS Number: Mixture
General Use: Adhesive
Manufacturer: Protective Coating Company, 221 S. Third St., Allentown, PA 18102-4922, Emergency Phone 1-800-255-3924,
International + 01 or +001-813-248-0585 (Please call collect if necessary) (24 Hr) CHEM-TEL
Contact Phone (610)432-3543, FAX (610)432-5043 (9AM-5PM EST)
Section 2 - Composition / Information on Ingredients
Ingredient Name CAS Number PEL TLV STEL
Diglycidyl Ether of Bisphenol A 25085-99-8 NE NE NE
Ethylene Glycol (parts A, B) 107-21-1
C 50 ppm C 100ppm
NE
Silica, crystalline (parts A, B) 14808-60-7
0.1mg/m
3
0.1mg/m
3
NE
Section 3 - Hazards Identification
 Emergency Overview 
HMI
S
H
F
R
2
1
0
PPE
†B
Sec. 8
Potential Health Effects
Acute Effects
Inhalation: none
Eye: moderate eye irritation or sensitization.
Skin: moderate skin irritation or sensitization.
Ingestion: possible irritation.
Carcinogenicity: IARC, NTP, and OSHA do not list PC Concrete Epoxy, Part A as a carcinogen.
Medical Conditions Aggravated by Long-Term Exposure: skin and eye conditions.
Section 4 - First Aid Measures
Inhalation: Remove to fresh air.
Eye Contact: Flush with water, consult a physician.
Skin Contact: Wash with water, consult a physician.
Ingestion: Seek medical advice.
After first aid, get appropriate in-plant, paramedic, or community medical support.
Section 5 - Fire-Fighting Measures
1
1
0
NFPA
Flash Poin
t: >300 F
Flash Point Method: Closed Cup
Flammability Classification: IIIB
Extinguishing Media: Water spray, CO
2, dry chemicals.
Unusual Fire or Explosion Hazards: None known.
Hazardous Combustion Products: Carbon monoxide, carbon dioxide, aldehydes
Fire-Fighting Instructions: Do not release runoff from fire control methods to sewers or waterways.
Fire-Fighting Equipment: Because fire may produce toxic thermal decomposition products, wear a self-contained breathing
apparatus (SCBA) with a full facepiece operated in pressure-demand or positive-pressure mode.
Section 6 - Accidental Release Measures
Spill /Leak Procedures: Dispose of in normal manner.
Disposal: Incinerate in furnace of bury in landfill according to applicable regulations; not a hazardous waste.
Regulatory Requirements: Follow applicable OSHA regulations (29 CFR 1910.120).

Summary of content (6 pages)