Specification

R-25209_000 2021 07 06 RPT - Peak AQ - 2020 FRC 2020 FBC.docm Page 3
Conform FBC 454.2.17.1.5
FRC R4501.17.1.5
Where the barrier is composed of
horizontal and vertical members
and the distance between the tops
of the horizontal members is 45
inches or more, spacing between
vertical members shall not exceed
4 inches. Where there are
decorative cut-outs within vertical
members, spacing within the cut-
outs shall not exceed 1-3/4 inches
in width.
Aquatine horizontal
members are spaced 45-
½ - inches apart.
Aquatine vertical
members are spaced 4-
inches maximum
between.
N/A FBC 454.2.17.1.6
FRC R4501.17.1.6
Maximum mesh size for chain link
fences shall be a 2-1/4 inch
square unless the fence is provided
with slats fastened at the top or
bottom which reduce the openings
to no more than 1-3/4 inches.
Aquatine does not have
chain-link barriers.
N/A FBC 454.2.17.1.7
FRC R4501.17.1.7
Where the barrier is composed of
diagonal members, the maximum
opening formed by the diagonal
members shall be no more than 1-
3/4 inches.
Aquatine does not have
diagonal members.
Conform FBC 454.2.17.1.8
FRC R4501.17.1.8
Access gates shall be equipped to
accommodate a locking device on
the pool side of the gate, opening
outward from the pool, and shall
be self-closing and have a self-
latching device
Aquatine gate is
equipped with self-
latching device, hinge
self-closes, opens away
from the pool.
Conform FBC 454.2.17.1.8
FRC R4501.17.1.8
Where the device release is located
no less than 54 inches from the
bottom of the gate, the device
release mechanism may be located
on either side of the gate and so
placed that it cannot be reached by
a young child over the top or
through any opening or gap from
the outside.
Aquatine latch device is
located 54 inches from
the bottom of gate.
Conform FBC 454.2.17.1.8
FRC R4501.17.1.8
The gates and barrier shall have no
opening greater than 1/2 inch
within 18 inches of the release
mechanism.
Aquatine latch device is
located 54 inches from
the bottom of gate.
See Appendix B for
additional information.
N/A FBC 454.2.17.1.9
FRC R4501.17.1.9
When a wall of a dwelling serves as
part of the barrier.
Aquatine fencing barrier
is not part of a dwelling.
N/A FBC 454.2.17.1.10
FRC R4501.17.1.10
Where above-ground pool structure
is used as a barrier or where the
barrier is mounted on top of the
pool structure, and means of
access is a ladder or steps, the
ladder or steps either shall be
capable of being secured, locked
or removed to prevent access, or
the ladder or steps shall be
surrounded by a barrier.
This section not
applicable.
N/A FBC 454.2.17.1.11
FRC R4501.17.1.11
Standard screen enclosures may be
utilized as part of or all of the
barrier.
This section not
applicable.