Specification

R-25209_000 2021 07 06 RPT - Peak AQ - 2021 ISPSC.docm Page 4
Conform 305.3.3.1 Where door and gate latch release
mechanism are accessed from the
outside of the barrier and are not of the
self-locking type, such mechanism shall
be located above the finished floor or
ground surface in accordance with the
following:
At public pools and spa, not
less than 52 inches and not
greater than 54 inches.
At residential pools and spas,
not less than 54 inches.
Aquatine barrier system
is located not less than
54 inches from grade or
finished floor for
residential pools and
spa.
N/A 305.3.3.2 Where door and gate latch release
mechanisms are of the self-locking type
such as where the lock is operated by
means of a key, an electronic opener or
the entry of a combination into an
integral combination lock, the lock
operation control and the latch release
mechanism shall be located above the
finished floor or ground surface in
accordance with the following:
At public pools and spas, not
less than 34 inches and not
greater than 48 inches.
At residential pools and spas, at
not greater than 54 inches.
Aquatine gate latch is
not self-locking. This
does not apply.
N/A 305.3.3.3 At private pools, where the only latch
release mechanism of a self-latching
device for a gate is located on the pool
and spa side of the barrier, the release
mechanism shall be located at a point
that is at least 3 inches below the top of
the gate.
Aquatine gate latch is
located on the outside of
the gate. This does not
apply.
N/A 305.3.4 Where a latch release mechanism is
located on the inside of a barrier,
openings in the door, gate and barrier
within 18 inches of the latch shall not
be greater than ½ inch in any
dimension.
Aquatine gate latch is
located on the outside of
the gate. This does not
apply.
N/A 305.4 Structure/Dwelling wall as a barrier. Does not apply to the
Aquatine fence system.
N/A 305.5 Onground residential pool structure as a
barrier.
Does not apply to the
Aquatine fence system.
N/A 305.6 Natural barriers.
Does not apply to the
Aquatine fence system.
N/A 305.7 Natural topography. Does not apply to the
Aquatine fence system.