Instruction Manual

DC Current
Range
Resolution
Accuracy
20 mA
10 µA
+/- (1.5% + 3 dgt.)
200 mA
100 µA
Overload Protection: FF 400 mA/600 V (6.3 x 32mm)
Max. Input: 200 mA DC/AC
rms
AC Current
Range
Resolution
Accuracy
20 mA
10 µA
+/- (2.0% + 3 dgt.)
200 mA
100 µA
Overload Protection: FF 400 mA/600 V (6.3 x 32mm)
Frequency range: 40-200 Hz
Max. Input: 200 mA DC/AC
rms
Resistance
Range
Resolution
Accuracy
200
0.1
+/- (1.0% + 3 dgt)
2 k
1
+/- (1.0% + 1 dgt)
20 k
10
200 k
100
2 M
1 k
20 M
10 k
+/- (1.0% + 5 dgt)
Overload Protection: 250 V DC/AC
rms
Open circuit voltage: approx. 250 mV
-30-