3.6. Resistance
Range
Resolution
Short Circuit
current (ca.)
Open
Circuit
Voltage
Accuracy
200
0.01
1 mA
1 V
± 0,5%
+ 30 dgt.
2 k
0.1
100 µA
± 0,8%
+ 5 dgt.
20 k
1
10 µA
200 k
10
1 µA
2 M
100
0.2 µA
0.5 V
20 M
1 k
0.2 µA
± 2,0%
+ 25 dgt.
20 M
10 k
± 5%
+ 30 dgt.
Overload protection: 250V DC/AC
rms
Measuring error does not include test lead resistance
3.7. Frequency
Range
Resolution
Accuracy
200 Hz
0.01 Hz
0,5% + 4 dgt.
2 kHz
0.1 Hz
20 kHz
1 Hz
200 kHz
10 Hz
2 MHz
100 Hz
20 MHz
1 kHz
For a signal less than 3Hz, the reading should be zero
500mV ≤ input range ≤ 30V RMS
Overload protection: 250V DC/AC
r
ms
3.8. Temperature
Range
Resolution
Accuracy
-20... +1000°C
0.1°C
1,0% + 50 dgt.(< 620°C)
1°C
1,5% + 15 dgt. (> 620 °C)
-20… +1832°F
0.1°F
1,0% + 50 dgt.(< 620°F)
1°F
1,5% + 15 dgt. (>620 °F)
Overload protection: 250V DC or AC
rms
Sensor: K-Type Thermocouple (NiCr-NiSi)