User Manual
Meg Ohms
Terminal
Voltage
(open circuit
voltage)
Range
Reso-
lution
Accuracy
Test Current
Short
circuit
current
125V
(0%~+10%)
0.125~4.000 MΩ
0.001 MΩ
+(2%+10)
1 mA (+ 10%) @
load 125kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(4%+ 5)
400.1~4000 MΩ
1 MΩ
+(5%+ 5)
250 V
(0%~+10%)
0.250~4.000 MΩ
0.001 MΩ
+(2%+10)
1 mA (+ 10%) @
load 250kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(3%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)
500 V
(0%~+10%)
0.500~4.000 MΩ
0.001 MΩ
+(2%+10)
1 mA (+ 10%) @
load 500kΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+10)
40.01~400.0 MΩ
0.1 MΩ
+(2%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)
1000 V
(0%~+10%)
1.000~4.000 MΩ
0.001 MΩ
+(3%+10)
1 mA (+ 10%) @
load 1MΩ
≥1mA
4.001~40.00 MΩ
0.01 MΩ
+(2%+ 10)
40.01~400.0 MΩ
0.1 MΩ
+(2%+ 5)
400.1~4000 MΩ
1 MΩ
+(4%+ 5)
-12-