User Manual

DC Current
Range
Accuracy
Resolution
2000 µA
± 1,0 % + 2 digit
1 µA
20 mA
10 µA
200 mA
± 1,2 % + 2 digit
100 µA
10 A
± 2,0 % + 2 digit
10 mA
Overload protection: µA/mA-ranges: 0,2 A/250 V fuse
10A-ranges: 10A/250V fuse
maximum input current: 10 A
Resistance
Range
Accuracy
Resolution
200 Ω
± 0.8 % + 2 digit
0.1 Ω
2000 Ω
1 Ω
20 kΩ
10 Ω
200 kΩ
100 Ω
2000 kΩ
± 1,0 % + 2 digit
1 kΩ
Max. open circuit: under 2,8 V
Overload protection: 220 V
eff
in all ranges (max. 15 sec.)
Diode Test
Range
Description
Test Conditions
Display read approx.
forward voltage of
diode
Forward DC current
1 mA.
Reversed DC voltage
approx. 2,8 V.
-19-