User Manual

34. How to Use Executive Buttons
Executive Buttons include Autoset, Run/Stop, Single, Copy.
34.1. Autoset
This button is used for the automatic setting of all control values of the instrument to generate the waveform
suitable for observation. Press the Autoset button and the oscilloscope will perform the fast automatic
measurement of the signal.
The function items of Autoset are shown as the following table:
Function Items
Setting
Acquisition Mode
Current
Vertical Coupling
DC
Vertical Scale
Adjust to the proper division.
Bandwidth
Full
Horizontal Level
Middle
Horizontal Sale
Adjust to the proper division
Trigger Type
Current
Trigger Source
Show the minimum number of channels.
Trigger Coupling
Current
Trigger Slope
Current
Trigger Level
Mid-point Setting
Trigger Mode
Auto
Display Format
YT
34.2. Run/Stop
Enable or disable the waveform sampling.
Notice: Under the Stop state, the vertical division and the horizontal time base of the waveform can be
adjusted within a certain range, in other words, the signal can be expanded in the horizontal or
vertical direction. When the horizontal time base equal to or is less than 50ms, the horizontal time
base can be expanded for 4 divisions downwards.
34.3. Single
Press this button you can set the trigger mode as single directly, so when trigger occurs, acquire one
waveform then stop.
-155-