User Manual
Method B:
Using two 0-5K Ohm variable resistors
Remark: variable resistors 5KOhm
Remote Socket Pin Assignment for variable resistor
PIN Functions Remarks
1 Internal DC +5V Resistor end
2 Voltage Adjust Variable part of resistor
3 Current Adjust Variable part of resistor
4 Ground Another resistor end
5 Output OFF Short to Ground
6 N.A.
7 N.A.
8 N.A.
Check the output voltage range of the power supply by adjusting the 5Kohm variable resistor.
Short circuit the main output with 10AWG wire to check the display for CC setting by adjusting
the variable resistor.
9.2 Remote Output ON/OFF Control (PeakTech 1525/1535)
This remote output on/off control can be activated in any of the modes Normal, Preset, Remote
and Set mode.
1. By default, Pin 5 is open and output is on.
2. Shorting Pin 5 to Pin 4 (ground) and output is off.
3. When output is off, the C.V. & C. C. LED´s will flash. The current output voltage and
current setting will show on the panel meter.
4. You can also adjust the output by voltage & current control knob to your desired value,
when output is off.
Remark: using the 8pin remote plug provided and connect with 22AWG wires.
-30-
Pin numbers are
marked on the black
portion.