User Manual
To
Port 1
To
Port 4
2. Use Only wires from port 2 and 4. Then, connect port 2 to positive polarity of the external
voltage source and port 4 to negative polarity of the external voltage source.
3. Switch on the power supply.
4. Vary the external input voltage 0 – 5 V to check and verify for the full output voltage range
of power supply.
5. Switch off the power supply.
Method B:
Using 5 kΩ Variable Resistor
1. Make sure the load is disconnected and the power supply is OFF.
2. Prepare a 5 kΩ variable resistor and use wires from port 1, 2 and 4.
To Port 2
VVVV
3. Switch on the power supply.
4. Adjust the 5 kΩ variable resistor from one end to other end to check and verify for the full
output voltage range of power supply.
5. Switch off the power supply.
9.4 Current Remote Control
a.) Using the same connector plug in section 9.1. Remove the black portion of the remote
control connector plug by removing the screw.
1. Remove the screw
2. Rotate the black portion
3. Black portion / silver portion
-32-