User Manual

3.2. Specifications
Function
Range
Output
Sensitivity
Accuracy (of
reading)
AC Current
(50/60 Hz)
0 ~ 200 A
1 mV/A 1 A/mV AC +/- 2,0 %
+/- 0,5 A
Accuracy System Accuracy: Current clamp accuracy + DMM
accuracy
Example with multimeter for the AC Current Clamp-on
Adaptor
Current Clamp sensitivity = 1 mV/A.
Multimeter displays 100.0 mV.
Actual current = display value
sensitivity Current Clamp = 100.0 mV/1 mV/A = 100.0 A
4. Application Procedures
1. Insert the black banana plug into the COM jack and the red
banana plug into the V- jack of any multimeter.
2. Switch-on the multimeter and set it to mV-voltage range.
3. Position the current clamp perpendicular to and centered
around conductor and read the measured value from the
display of multimeter.
-10-