User Manual

Duty Cycle
Range
Resolution
Scope (%)
Accuracy
Duty 0,1% 5 % ~ 95% ± 2,0% rdg. + 7 dgt.
The Duty range is an autorange
Input voltage 4 ~ 10 Vp-p
Frequency Range: 4Hz ~ 1kHz
Overload protection: 600V AC/DC
Diode
Range
Resolution
Test current
Open circuit voltage
1 mV about 0,8 mA about 3 V
Overload protection: 600V AC/DC
Continuity
Range
Int
roduction
Remark
.
))
)
The built-in buzzer will sound if
the resistance is less than
about 20 . The buzzer will not
sound if the resistance is more
than about 150 .
Open Circuit voltage:
< 0,7 V
Overload protection: 600V AC/DC
-56-