Datasheet

8. Technical Specifications
Display
3 ½ - digit, two-line LCD-display with
backlight
Measuring range
-50 ~ 260°C
Sample rate
2,5 x / second
Spectral sensitivity
8 ~ 14 um
Emissivity
0.95 (fixed)
Response time
150 ms
Laser
Class 2,
Output < 1 mW,
Wavelenght 630 670 nm
Optical resolution (DS)
12 : 1
Operating temperature
0°C 50°C (32°F … 122°F)
Storage temperature
-10°C 60°C (14°F140°F)
Relative Humidity
10 90% (non condensing)
Power supply
9V - battery
Dimesions (WxHxD)
62 x 182 x 92 mm
Weight
160g
8.1. Specifications
Infrared-Range
Measuring Range
Resolution
Accuracy
-50 … +0°C
(-58 … +32°F)
0,1 °C / °F
+/- 3,5°C
0 … + 260°C
(32 … 500°F)
+/- 1,0% + 1°C
Note!
Accuracy at 18 ° C to 28 ° C and Humidity less than 80%.
Field of View:
Make sure that the target to be measured is bigger than the laser beam.
The smaller the target, the closer you should be located to it during
measurement. If the accuracy is not given, make sure that the target is 2
x larger than the laser beam.
-33-