Contents 1.0 INTRODUCTION ........................................................................................... 3 2.0 FEATURES .................................................................................................. 3 3.0 FRONT PANEL DESCRIPTIONS ......................................................................... 4 4.0 REAR PANEL DESCRIPTIONS ........................................................................... 5 5.
PFC'" 20 Professional MIDI Foot Controller 1 .O INTRODUCTION Congratulations on your purchase of the PFCTM 10 Professional MIDI Foot Controller. This MIDI foot controlleris designed to operate as either a stand-alone MIDI program change and continuous controller,orin conjunction with the Peavey Tube Fex'" or TransFex'" 212 as an intelligent program change and continuous controller. 2.
PFC” IO Professional MIDI Foot Controller Display I I Bank/Program Numbered Button 3.0 FRONT PANEL DESCRIPTIONS 1. Display Tuner LED B,mk/Tuner Button I I I Program LED This is a 20-character by 2-line Liquid Crystal Display (LCD) with variable view angle adjustment for easy visibility. 2. Tuner LED Blinking red indicates that the tuner is active. 3. Bank/Tuner Button Pressing the Bank/Tuner button once selects Bank mode. Then, pressing a "Numbered" button once selects a Bank.
PFC'" 10 Professional MIDI Foot Controller View Angle Adjust MIDI/ Remote OutJcd Control Voltage Jarits 4.0 REAR PANEL DESCRIPTIONS 1. Power Supply Required when using a 5-pin MIDI cablewith MIDIequipment otherthan theTube FexorTransFex 212. Use onfy the 16-16.5 volt AC 1,000 mA adaptor, Peavey part#70900660, available as an option. Caution: Use only the optional16.5 volt power supply for this product.
PFC‘" 10 Professional MIDI Foot Controller 5.0 CONNECTING THE PFC 10 PROFESSIONAL MIDI FOOT CONTROLLER 5. I WITH THE TUBE FEX OR TRANSFEX 212 When used with the Peavey Tube Fex or TransFex 212, the only connection required is that of the supplied 8-pin DIN cable. This cable provides power from the Tube Fex or TransFex 212 to the foot controller, as well as supporting bidirectional MIDI transmission. Caution: The 8-pin cable is not a standard MIDI cable.
PFC’” 10 Professional MIDI Foot Controller Forexample: If you are currently on program A4 and wish to change to program A58, press the Bank button once and press the 5th numeric button to select bank 5. As soon as you press the 8, Program Change 58 is transmitted. Now, if you press 3, Program Change 53 will be transmitted. A typical display on the controller will appear as follows: In the top left corner of the display is a letter followed by a number. The number is the PROGRAM number.
PFC'" 10 Professional 7.0 MIDI Foot Controller USING THE CONTROLLER AS A STAND-ALONE MIDI CONTROLLER All messages transmitted by the PFClO Professional MIDI Foot Controller are standard MIDI messages. When used with a standard, 5-pin MIDI DIN cable, the controller will transmit Program and CV messages. Each timeyouturnthe footcontrolleron,you need to setthe MIDI channelthatthefoot controller will transmit on.
PFC'" 10 Professional MIDI Foot Controller For further information on other Peavey products, ask your Authorized Peavey Dealer for the appropriate Peavey catalog/publication.
THIS LIMITED WARRANTY VALID ONLY WHEN PURCHASED AND REGISTERED IN THE UNITED STATES OR CANADA. ALL EXPORTED PRODUCTS ARE SUBJECT TO WARRANTY AND SERVICES TO BE SPECIFIED AND PROVIDED BY THE AUTHORIZED DISTRIBUTOR FOR EACH COUNTRY. Ces clauses de garantie ne sont vaiables qu’aux Etats-Unis et au Canada. Dans tour les autres pays, les clauses de garantie et de maintenance sont fixees par le distributeur national et assuree par lul seion la legislation envigueur.
IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric products, basic cautions should always be followed, including the following: 1. Read all safety and operating instructions before using this product. 2. All safety and operating instructions should be retained for future reference. 3. Obey all cautions in the operating instructions and on the back of the unit. 4. All operating instructions should be followed. 5. This product should not be used near water, i.e.
Features and specifications subject to change without notice. A Peavey Electronics Corporation 711 A Street / Meridian, MS 39301 / U.S.A. / (601) 483-5365 / Fax 486-1278 01996 #80300362 Printed in U.S.A.