Manual

LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
SPECIFICATIONS
__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________
2246 5th Street, Berkeley, CA 94710 Tel: 510.845.2760 Fax: 510.845.2776 Email: techsupport@peerlesslighting.com PeerlessLighting.com
Type: ________________________
Project: ______________________
1
© 2013 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Cerra” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Indirect T8
10CRM7  Cerra 10  Partial Perforation
Suspended 10CRM7
Cerra 10
Partial Perforation
Indirect T8
Examples: 10CRM7 2 32 WHR 40FT R12 277 GEB10 DCT LP835 F1/18 C210 SCEP — 10CRM7 3 32 SPR 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
SCEP Option
10CRM7 - 2
2
5
8
10”
10CRM7 - 3
2
5
8
10”
10CRM7 - 4
2
5
8
10”
Notes:
1 Refer to photometric test for exact distribution
2 Available with 3-lamp cross section only
3 Not available in 347V
4 EL and EC are installed in last 4’ of luminaire sections and
are not available concurrently with each other. Separate
feed required for each EL or EC unless ELH is specified
_______ ________ _______ __________ _________ __________ _________ __________
Luminaire
10CRM7
# of Lamps in
Cross Section
2
3
4
Lamp Type
32 32W T8
Distribution
1
WHR White Reflector
(Standard)
SPR Specular
Luminaire
Row Length
X FT
(4’ increments)
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10 <10% THD Electronic
ADEZ
3
Advance Mark 10 dim
DMHL3D
3
Lutron Hi-Lume dim
ADZT
3
Advance Mark 7 0-10V dim
Reference Ballast Wizard on website
or consult factory for other options.
# of Emergency Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
______________ __________ ________________ ______________ ______________ ______________ _________________________________
Emergency Type
4
(Blank) None
EC Emergency circuit
EL
3
Emergency battery pack
EN
3
Emergency battery pack
w/night light circuit
Switching
SCT Single circuit
DCT Dual circuit
Lamp Color
L/LP No lamp
L/LPE No lamp. Wired
for energy saving
lamps.
LP830 3000K 80+ CRI
LP835 3500K 80+ CRI
LP841 4100K 80+ CRI
Reference Lamp Chart on
website or consult factory
for other options.
Mounting Type /
F1/ T-bar ceiling (universal
mounting bracket)
F1A/ T-bar ceiling (UMB with
integrated J-box)
F2/ Hard ceiling (horizontal
J-box)
F3/ Rigid stem
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24
XX XX”
Overall
suspension is
measured from
ceiling to bottom
of luminaire.
Finish
C110 Painted
aluminum (low
gloss)
C210 White white
(fine-textured
low gloss)
C099 Custom finish
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy
(not available with F3)
CP Chicago plenum (available with F1A only)
DL Damp location label
DU Dust cover
ELH Emergency through wiring w/separate
feed
ELS Emergency through wiring w/single feed,
shared neutral
ELS2 Emergency through wiring w/single feed,
separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/
zone
NYC New York City code
OJB Oset junction box
SCEP Sculptured end cap
SLP Sloped ceiling (for 10-45°, must be
specified with F2, ACG and OJB options)
XXXX Integrated sensor; choose options and
obtain code on page 2
Construction
Nominal 10” x 3” crescent housing is formed from
one-piece cold-rolled steel. Flat end plate standard.
Sculptured die-cast aluminum end cap is optional.
Reflectors
Die-formed highly reflective white or specular
reflector.
Shielding
Die-punched perforations on lower housing with
acrylic opal diuser overlay.
Finish
Fine-textured, white or aluminum polyester
powder paint. Custom colors available,
consult factory.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’, 8’, and 12’ lengths in a single section for exact
suspension spacing of 4’, 8’, and 12’. For total
luminaire length, add
1
16” for each flat end plate
or 4” for each sculptured end cap. Using internal
joiners, 4’, 8’, and 12’ sections can be joined to form
longer length luminaires.

Summary of content (2 pages)