LAMPING OPTIONS
SPECIFICATIONS
CATALOG NUMBER
SPECIFICATIONS
2246 5th Street, Berkeley, CA 94710 Tel: 510.845.2760 Fax: 510.845.2776 Email: techsupport@peerlesslighting.com PeerlessLighting.com
________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ ________ _____________________
BRM4 1 T5/T5HO WHR
BRM4 3 T5/T5HO WHR
BRM4 2 T5/T5HO WHR
BRM4 1 T5/T5HO WHR
BRM4 3 T5/T5HO WHR
BRM4 2 T5/T5HO WHR
BRM4 1 T5/T5HO WHR
BRM4 3 T5/T5HO WHR
BRM4 2 T5/T5HO WHR
Type: ________________________
Project: ______________________
1
© 2013 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Peerless Bruno” are registered trademarks of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx
Indirect-Direct T5/T5HO
BRM4  Bruno I/D
Examples: BRM4 2 28T5 SPR SSB 40FT R8 277 GEB10 DCT LP835 F1/18 C210 SCEP — BRM4 3 54T5HO SPR WPB 32FT R8 277 GEB10 1SE EL DCT LP835 F1/21 C110
Construction
Nominal 8
1
4” x 1
3
4” rectangular housing is formed
from cold-rolled steel. Die-cast end caps are
mechanically attached with no exposed fasteners.
Reflectors
Die-formed specular reflector with 95% reflectance.
Shielding /Bae
Choose one of four parabolic bae options: semi-
specular, white painted, semi-specular perforated
blade or white painted, perforated blade. Each
available with optional acrylic opal overlay.
Finish
Fine textured white polyester powder
paint is standard. Consult factory for special
finish requirements.
Electrical
Specify 120V, 277V or 347V. Pre-wired with 16AWG
fixture wires. For special circuiting or wire gauge,
consult factory. Plug-in electrical connectors
included. UL and C-UL listed.
Luminaire Length
4’
3
8”, 8’ and 12’ lengths in a single section for
nominal support spacing at 4’, 8’ and 12’. For total
luminaire length, add
5
8” for each flat end cap
and 4” for each sculptured end cap. Using internal
joiners, 4’, 8’ and 12’ sections can be joined to form
longer rows.
Suspended BRM4
8
1
4
BRM4 - 1 BRM4 - 2 BRM4 - 3
1
3
4
1
2
8
1
4
1
3
4
1
2
8
1
4
1
3
4
1
2
________ _______ _______ __________ __________ __________ __________ _________ __________ _______ __________
Luminaire
BRM4
# of
Lamps
in
Cross
Section
1
2
3
Lamp Type
28T5
1
28W T5
54T5HO 54W T5HO
Reflector
SPR Specular
reflector
Distribution
(Blank) Standard
65/35
20/80
2
20% up,
80% down
40/60
2
40% up,
60% down
0/100
2
0% up,
100% down
CLI
3
Center lamp
isolater
Shielding
(Blank)
OPD Opal
overlay
Bae
SSB Semi-specular
bae
WPB White painted
bae
SSP Semi-specular
perforated
blade bae
WPP White painted
perforated
blade bae
Luminaire
Row
Length
X FT
(4’ increments)
Maximum
Section
Length
R4 4’ section(s)
R8 8’ section(s)
R12 12’ section(s)
Voltage
120
277
347
Ballast Type
GEB10 <10% THD
Electronic
ADEZ
1,4
Advance Mark
10 dim
DMHL3D
1
Lutron Hi-Lume
dim
OSDIM
1,4
Osram 0-10V
dim
Reference Ballast Wizard on
website or consult factory for
other options.
_______ _______ _______ ________________ ______________ ______________ ______________ _________________________________
# of
Emergency
Modules
(Blank) None
1SE 1 section
2SE 2 sections
XSE X sections
Emergency
Type
5
(Blank) None
EC Emergency
circuit
EL
1
Emergency
battery
pack
EN
1
Emergency
battery
pack
w/night
light
circuit
Switching
SCT Single
circuit
DCT Dual
circuit
Lamp Color
L/LP No lamp
LP830 3000k 80+ CRI
LP835 3500k 80+ CRI
LP841 4100k 80+ CRI
Available with T5 only:
LP830P 3000K 80+
CRI Premier
LP835P 3500K 80+
CRI Premier
LP841P 4100K 80+
CRI Premier
Reference Lamp Chart on
website or consult factory
for other options.
Mounting Type /
F1/ T-bar ceiling
(universal
mounting
bracket)
F1A/ T-bar ceiling
(UMB with
integrated
J-box)
F2/ Hard ceiling
(horizontal
J-box)
F3/ Rigid stem
Overall
Suspension
12 12”
15 15”
18 18”
21 21”
24 24
XX XX”
Overall
suspension
is measured
from ceiling
to bottom of
luminaire.
Finish
C110 Painted
aluminum
(low
gloss)
C210 White
white
(fine-
textured
low gloss)
C099 Custom
finish
Options
ACG Adjustable cable grippers
BLK Black cord, cord manager and canopy (not available with F3)
CP Chicago plenum (available with F1A only)
DL Damp location label
DU
6
Dust cover
ELH Emergency through wiring w/separate feed
ELS Emergency through wiring w/single feed, shared neutral
ELS2 Emergency through wiring w/single feed, separate neutrals
GLR Fusing (fast blow)
GMF Fusing (slow blow)
MCS Matching feed canopy at support
NEPP5D nLight enabled control module per row/zone
NYC New York City code
OJB Oset junction box
SCEP Sculptured end cap
SLP Sloped ceiling (for 10-45°, must be specified with F2, ACG and
OJB options)
XXXX Integrated sensor; choose options and obtain code on page 2
Notes:
1 Not available in 347V
2 Nominal distribution, refer to photometric tests for exact
distribution. Not available with DU option
3 Available with 3-lamp cross section luminaires only
4 Not available with 28T5 lamps
5 Emergency type is installed in last 4’ of luminaire sections
Separate feed required unless ELS or ELS2 is specified.
6 Not available with 3-lamp T5HO cross section
SCEP Option
Bruno I/D