Water Conditioning Equipment 1701 E. Vine St., P.O.
INSTALLATION DIAGRAM Specifications - 30 FME-XTR and 30 FME-S-XTR Rough in dimension: From the floor to the center of bypass approximately 50" for 30 FME-XTR, and approximately 36-1/2" for a 30 FME-S-XTR Maximum distance and size for drain line: 50' horizontal, 10" vertical rise, using 1/2" ID drain line Maximum distance and size for brine line: 15' horizontal (see note) using 1/4" ID poly tubing NOTE: The horizontal distance for the brine tank can be increasted to 35' if the brine tank is installed above t
INSTALLATION DIAGRAM Specifications - 30 FME-C-XTR Rough in dimension: From the floor to the center of bypass approximately 50" Maximum distance and size for drain line: 50' horizontal, 10" vertical rise, using 1/2" ID drain line The drain and brine lines should NOT be installed with tubing that can collapse. This will cause the unit to malfunction. CAUTION: Do NOT conenct drain line tubing from control valve to overflow fitting/tubing on brine tank.
Start-up Procedure Peerless 30 FME-XTR Series Softeners 1. Pipe ¾” or 1” inlet and outlet service piping, according to the print, and arrows on bypass and control valve.. 2. Set brine tank in place on a clean, level surface. This prevents bottom puncture when weight of water and salt are added. Connect brine line (furnished in brine tank) from brine tank to valve. Line must be air tight. 3. Connect 5/8” OD poly tubing (not supplied) from valve to suitable drain. DO NOT use ½” copper male adapter.
6700XTR Powerhead Assembly Part # 6700-Powerhead Page 4
Control Valve Assembly 3 3 3 3 3 3 3 3 6 6 6 3 6 6 6 6 6 20 6 3 1 7 7 7 6 38 7 7 7 7 40 43 37 38 2 34 4 8 25 19 42 26 15 30 24 Page 5 5
Control Valve Assembly Item No. Quantity Part No. Description 1 ........................ 1 ..........................19707-30 ........................... Valve Body, 5600 Upflow, Bayonet 2 ........................ 1 ..........................13255 ................................ Clip, Mounting 3 ........................1........................................................................Piston P0003 & Seal Kit 4 ........................ 1 ..........................13304 ................................
Meter Assembly 1 1 1 1 Item No. Quantity Part No. Description 1..................1 ................... 14038 ............................Cap, Meter, Electronic 5..................5 ................... 17798 ......................Screw, Slot Hex Wsh Hd 6..................1 ................... 13821 ......................Body, Meter, 5600 7..................1 ................... 13509 ......................Impeller, Meter 8..................4 ................... 12473 ......................
Bypass Valve Assembly, Non-Metallic 4 Item No. Quantity Part No. Description 1..................2 ................... 13305 ......................O-ring, -119 2..................2 ................... 13255 ......................Clip, Mounting 3..................2 ................... 13314 ......................Screw, Slot Ind Hex, 8-18 x .60 4 .................1 ................... 41027-01 .................Yoke, 3/4”, NPT, Cast, Machd .......................................... 41026-01 .................
used in these models: Softeners: 20 FM/M and 30 FM/M, 30 FME-XTR, and 30 FME-S-XTR and 30 CME Filters: 10 NIT-W and 10 TF-W Our 474 safety brine valve system incorporates the 474 air check assembly to provide higher flow rates and greater flexibility than traditional brine delivery systems. Featuring a 1/2” riser pipe, our 474 safety brine valve system is capable of providing brine draw and refill rates up to 1-1/2 gallons per minute.
2310 Brine Safety Valve used in these models: Softeners: 20/30 FMC(M), 30 FME-C-XTR, 60 FME-W, and 60 CME Filters: 13 TF-W 11 8 9 12 7 6 5 10 3 4 13 1 2 14 9 Figure 21: 2310 Safety Brine Valve Item Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 No.
Troubleshooting - Timer If an error is detected, an error screen will alternate with the main display screen every few seconds, and the LED light will be red. During an error condition, the unit continues to monitor the flow meter and update the remaining capacity. Once an error condition is corrected, the unit returns to the operating status it was in prior to the error, and regeneration resumes according to normal programming.
Troubleshooting - Control Valve Problem Cause Correction 1. Water conditioner fails to regenerate. A. Electrical service to unit has been interrupted A. Assure permanent electrical service (check fuse, plug, pull chain, or switch) B. Timer is defective. B. Replace timer. C. Power failure. C. Reset time of day. 2. Hard water. 3. Unit used too much salt. 4. Loss of water pressure. A. By-pass valve is open. A. Close by-pass valve. B. No salt is in brine tank. B.
Troubleshooting - Control Valve Problem Cause Correction 8. Softener fails to draw brine. A. Drain line flow control is plugged. A. Clean drain line flow control. B. Injector is plugged. B. Clean injector C. Injector screen plugged. C. Clean screen. D. Line pressure is too low. D. Increase line pressure to 20 P.S.I. E. Internal control leak E. Change seals, spacers, and piston assembly. F. Service adapter did not cycle. F. Check drive motor and switches. 9. Control cycles continuously. A.