INSTALLATION/OPERATION 100 Series Camclosure® Integrated Camera System ® With LowLight™ DSS Technology C2460M-A (7/03)
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .............................................................................................. 3 REGULATORY NOTICES ...................................................................................................................... 3 WELCOME ................................................................................................................................................... 4 INSTALL THE BACK BOX .....................................
IMPORTANT SAFEGUARDS AND WARNINGS 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load. 4.
WELCOME Thank you for purchasing Pelco’s Camclosure® integrated camera system with LowLight™, DSS (digital slow shutter) technology. Your new ICS100 Series surface mount dome system includes a high-resolution, low light, color camera with auto iris and varifocal lens. The LowLight color camera has extended DSS settings to enhance the low light performance of the camera by automatically adjusting the number of fields of integration.
INSTALL THE BACK BOX REMOVE THE LOWER DOME Loosen the tamper-resistant screws with the supplied 1/8-inch hollow screwdriver bit. Remove the lower dome and place it to the side.
Attach Directly to Concrete Wall/Ceiling Refer to Figure 2 for the following steps. 1. Attach the base to the wall or ceiling (hardware not supplied). 2. Do one of the following: Not Using Side Conduit Opening - Verify the set screw and side conduit cover are tight. Using Side Conduit Opening - Loosen the set screw and remove the conduit plug. Install a 3/4-inch (1.91 cm) conduit fitting and tighten the set screw. 3. Connect the video cable.
Mount to a Plaster Ring Refer to Figure 4 for the following steps. Installation instructions assume that the 4S electrical box and plaster ring were previously installed. 1. Pull video and power wires into the base. 2. Attach the base to the plaster ring. - Use the two 8-32 x .750-inch pan head screws to attach the base to a 401 plaster ring. - Use the three 6-32 x .750-inch pan head screws to attach the base to a 404 plaster ring. 3. Connect the video cable.
CONNECT POWER WIRES Depending on the input voltage, connect either the 12 VDC or 24 VAC input power wires to the terminal block inside the base. Refer to Figure 5 for the location of the terminal block. DC Operation – Refer to the enlarged portion of Figure 5 for the 12 VDC (+) and ground (-) connections. AC Operation – It does not matter which terminals the power wires are connected to.
INSTALL THE CAMERA MODULE CHECK HEATER JUMPER The Camclosure is equipped with a heater to defrost the dome. Some installations may not require this heater. If the unit will never be subjected to a frost temperature, you can disable the heater, saving power requirements. To disable the heater, remove the jumper cover from the J1 jumper block (refer to Figure 6). It is recommended that the jumper cover be left in the unit by installing it on one of the jumper pins. CAMERA CONNECTOR J1 JUMPER Figure 6.
INSTALL AND POSITION THE CAMERA 1. Plug the video connector from the camera into the mating connector inside the back box (refer to Figure 6). 2. Position the camera so that the tab on the camera bracket is pointing out of the enclosure, away from the ceiling or wall. Refer to the following illustrations for proper camera orientation.
MAKE CAMERA SETTINGS CAUTION: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models. DSS2 DSS1 AGC BLC ON OFF WHITE INDICATES SWITCH SETTING LEVEL PHASE N W ZOOM FOCUS T Figure 7. Default Switch Settings and Location of Camera Adjustments ZOOM/FOCUS 1. 2. 3. 4. Select a field of view by turning the zoom adjustment ring. Refer to Figure 7. Tighten the zoom locking screw.
AGC (AUTOMATIC GAIN CONTROL) AGC automatically adjusts the image to compensate for changes in light levels. ON (Default setting) – Enables the AGC mode. OFF – Disables the AGC mode. BLC (BACK LIGHT COMPENSATION) The BLC (backlight compensation) feature compensates for backlit scenes by enhancing objects in the center of the scene. OFF (Default setting) – Disables the BLC mode. ON – Enables the BLC mode.
REINSTALL THE LOWER DOME AND TRIM RING 1. Domes with Liners (only) – Position the viewing window over the lens of the camera. a. Loosen the three Phillip screws located in the dome. b. Insert the blade of a standard screwdriver in one of the adjustment grooves. Move dome into position. c. Tighten the three Phillip screws to lock liner in place. 2. Align the screw holes in the trim ring with those in the Camclosure base. 3.
SPECIFICATIONS BACKBOX Electrical Input Voltage: Power Consumption: Video Connector: 12 VDC or 24 VAC, ±10%, auto-sensing 13 watts or less BNC General Operating Temperature: -50° to 122°F (-46° to 50°C) De-ices to 25°F (-4°C) Pan/Tilt Adjustment: Manual; 360° pan; 180° tilt Construction: Aluminum with steel camera mounting bracket and polycarbonate dome Finish: White polyester powder coat Dimensions Above Ceiling: 1.75 (H) x 3.50 (W) inches (4.45 x 8.89 cm) Below Ceiling: 2.42 (H) x 5.48 (W) inches (6.
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • • • • • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras. Three years on Genex® Series (multiplexers, server, and keyboard) and 090 Series Camclosure® Camera System.