® CH1 CH2 CH3 CH4 PMCQ14A 14-Inch Color Quad Monitor Installation/ Operation Manual C1970M-A (7/01) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3 DESCRIPTION ................................................................................................................... 4 FEATURES ................................................................................................................ 4 OVERVIEW ................................................................................................................
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
DESCRIPTION FEATURES • • • • • • • • • • • • Observe up to Four Camera Images at Once or in Sequence Programmable Dwell Time for Each Camera During Sequence Mode Picture-In-Picture (PIP) View in Horizontal or Vertical Format 2X Digital Zoom and Freeze Functions Alarm Inputs for Each Camera Channel on Back of Monitor Alarm Causes Channel to Come up with Full View Programmable TTL Compatible Alarm Output on Monitor Video Loss Detector Sets Alarm Beep 4 Camera Inputs Through Mini-DIN or BNC Connectors Looping
EH3500 IMAGEPAK OUTDOOR W/ HEATER & DEFROSTER CH1 MCS4-2 POWER SUPPLY 24 VAC TO ALL INDOOR CAMERAS DF5 PENDANT DOMEPAK INDOOR WCS1-4 CH1 CH2 CH3 CH4 POWER SUPPLY CH2 CH3 CH4 PCMQ14A DF5 IN-CEILING EH100 DOMEPAK INDOOR IMAGEPAK INDOOR TLR2024 VIDEO CASSETTE RECORDER Figure 1. Typical Application Using PMCQ14A Monitor CH 1 BACK DOOR CH 2 FRONT DOOR CH 1 CH 2 CH 3 CH 4 CH 3 STOCK ROOM CH 4 CASH CHECKOUT Figure 2.
INSTALLATION NOTE: The mini-DIN (IN) connectors are for use with CCQ1400A-4 cameras. 1. Place monitor on a stable surface such as a shelf or desk top. 2. Connect cameras or alternate video sources to the desired channel IN/OUT connectors on the back of the monitor (refer to Figure 3). 3. Set impedance switches to the 75-ohm position (refer to Figure 3). 4. If alarm contacts are used, run wires from the contacts to the monitor and connect at the push-in connector on the back (refer to Figure 3). 5.
PROGRAMMING RETURNS TO DEFAULT (ALT+MENU ENTERS/EXITS SETUP MENU) RESET ALT FRONT PANEL PROGRAMING BUTTONS ZOOM FREEZE PIP SEQ QUAD MENU TINT CH1 CH2 CH3 CH4 VCR TALK AUDIO SHARP COLOR BRIGHT CONTRAST VOLUME POWER MIC Figure 4. Control Locations on Front of Monitor Table A . Programming Menu Press ALT + MENU to toggle in or out of the programming menu. Menu Item Function Procedure [1] ID INPUT Change channel name that appears on the screen. a.
CHECK OUT Table B. Check-Out Procedure This procedure assumes that power is on. Step Procedure Results 1 Calibrate cameras. Follow the manufacturer’s recommendations for calibration. 2 Press the QUAD/MENU button. See quad display. 3 Press the CH 1 button. See channel 1 image full screen. 4 Press the CH 2 button. See channel 2 image full screen. 5 Press the CH 3 button. See channel 3 image full screen. 6 Press the CH 4 button. See channel 4 image full screen. 7 Press the PIP/SEQ button.
MENU MODE QUAD MODE RESET QUAD ALT MENU QUAD MENU PIP MODE (HORZ) PIP SEQ SEQUENCE MODE RESET ALT PIP SEQ SINGLE-CAMERA MODE CH2 CH1 RESET ALT ZOOM FREEZE PIP SEQ CH3 QUAD MENU TINT CH1 CH2 CH3 CH4 VCR CH4 VCR TALK AUDIO SHARP COLOR BRIGHT CONTRAST VOLUME POWER MIC Figure 5.
INTERCOM NOTE: The intercom function is available only when CCQ1400A-4 cameras are used. The intercom operates with one camera at a time. When the monitor is in quad display mode, a speaker icon appears next to the channel number to show which camera has the intercom active. SPEAKER SYMBOL SHOWS WHICH CHANNEL IS IN INTERCOM MODE. RESET TALK ALT AUDIO PRESS ALT + AUDIO TO CHANGE INTERCOM CHANNEL. Figure 6. Intercom Activities on Screen Table D.
ALARM The alarm operates with any or all cameras at once. ALM flashes at the top center of the screen and the display automatically switches to show the camera that has the alarm. ALARM CAUSES THE ALARMED CHANNEL TO SHOW FULL SCREEN, ALM BLINKS, BEEP SOUNDS (IF ON). RESET ALT PRESS RESET TO ACKNOWLEDGE ALARM & STOP BEEP. DISPLAY RETURNS TO THE ORIGINAL MODE. WHEN THE ALARM GOES AWAY, THE CYCLE STARTS OVER. Figure 7. Alarm Activities on Screen Table E.
2 4 5 6 7 Hi 75 Hi 75 Hi 75 Hi 75 3 75 MAIN Hi VIDEO AUDIO IN IN CH 1 CH 2 CH 3 CH 4 MONITOR OUT OUT IN/OUT A/C INLET FOCUS SCREEN CH 1 CH 2 CH 3 CH 4 TRIG OUT 1 REMOTE* 10 11 8 9 13 12 14 15 Figure 8. Monitor Back Panel Controls and Connections Table F. Back Panel Reference Key Reference Number 12 Description Function 1 Power inlet Accepts 110 to 240 Volts AC, 50/60 Hz power. 2 Main power switch Controls power to monitor and cameras.
1 2 3 4 RESET ALT ZOOM FREEZE PIP SEQ QUAD MENU CH1 CH2 CH3 6 7 8 5 CH4 VCR TALK AUDIO 9 10 11 TINT SHARP COLOR BRIGHT CONTRAST VOLUME POWER 12 13 14 15 16 17 18 MIC Figure 9. Monitor Controls Table G. Front Panel Reference Key Reference Number Description Function 1 Reset/ALT key Resets alarm or video loss detection. When there is no alarm, use as ALT key to activate the alternate functions of the Zoom, PIP, Quad, CH4, and Talk keys.
TECHNICAL SPECIFICATIONS ELECTRICAL Input Voltage: Power Consumption: Signal Format: Scanning System: Picture Elements: Horizontal Resolution: Linearity: Audio Output: Pixel Format Single Screen: Quad Screen: PIP Screen: Refresh Rate: Digital Zoom: OSD Character: Video Switching Time When Multiple Alarms Occur: Maximum Character Display Format: 100 to 240 VAC, 50/60 Hz 70 watts NTSC 2:1 interlace 512 (H) x 492 (V) 350 TV lines (center) Less than 12% 1.1 W +/-0.
ENVIRONMENTAL Operating Temperature: Storage Temperature: Humidity: 32° to 104°F (0° to 40°C) 4° to 158°F (-20° to 70°C) 35% to 80%, non-condensing (Design and product specifications subject to change without notice.) REGULATORY NOTICES Note: This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard).