I N S T A L L A T I O N TW3004AR Active Receiver Four Channels for UTP Transmission C1667M (6/06)
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules.
Description The TW3004AR is a four-channel active receiver that can receive live video over unshielded twisted pair (UTP) cable. The adaptive technology in the TW3004AR automatically adjusts the low, medium, and high frequency components of the video signal, allowing for the best possible video transmission. The adaptive technology eliminates the need for manual adjustment by automatically adjusting to provide the most favorable video transmission depending on cable length needed.
PARTS OF THE RECEIVER v FRONT BACK L BOTTOM Figure 1. TW3004AR Parts Rubber Feet (4): For placing unit on a flat surface, such as a desk or shelf. Status LEDs (4): Light red when there is no UTP video being received. Light green when there is UTP video being received. Flash amber when Coaxitron pan/tilt/zoom (PTZ) control commands are being received. Pelco Badge: Lights blue to indicate power when using either the 4-pin rack power connector or the 2-pin power connector.
Installation The following parts are supplied: 1 1 1 1 1 Universal power supply (Part #PS04-1502-0512G) Wall clip with screws and washers Power connector 2-pin UTP mating connector Screwdriver MOUNTING The TW3004AR receiver is 3 rack units high and can be mounted into a fiber rack, onto a wall using a fiber wall mount kit or into the supplied wall clip. USING A RACK You can mount a TW3004AR into either an RK5000PS-3U (with power supply) or an RK5000-3U (without power supply).
USING A WALL CLIP To attach the TW3004AR receiver to a wall using the supplied wall clip, refer to Figure 2 and do the following: 1. Attach the wall clip to a wall using two screws (not supplied). 2. Slide the receiver into the clip until the two holes on the bottom of the receiver align with the two holes on the lower flange of the clip. 3. Attach the receiver to the clip using the two Phillips pan head screws provided with the clip.
SETTING THE DIP SWITCHES The factory default switch positions are shown in Figure 3. Switches 2-5 are set to auto and switch 1 is set to H mode. These settings ensure that the adaptive technology in the TW3004AR automatically adjusts the low, medium, and high frequency components of the video signal, allowing for the best possible video transmission. Figure 3.
APPLICATIONS You can connect the TW3004AR active receiver to transmitters, such as the TW3001P passive transceiver, and the TW3001AT active transmitter, and to Pelco UTP cameras, such as the CC3710/ CC3610 series. Although you can connect these products using an unshielded twisted pair Cat3 and Cat5 cable, Cat5e and Cat 6 are recommended for the best video performance. Always connect the UTP wires on the Cat cable from + to + and from – to –.
Figure 4 shows a TW3004AR connected to a UTP camclosure. TW3004AR POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY CAMCLOSURE UTP BLUE WIRE = MONITOR MONITOR GRAY WIRE = MONITOR MONITOR Figure 4.
Figure 5 shows a TW3004AR connected to a UTP fixed camera. TW3004AR POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY FIXED CAMERA UTP PIN 5 + MONITOR MONITOR MONITOR MONITOR PIN 4 - 10 PINS (5-/6+) 8 PINS (4-/5+) Figure 5.
Figure 6 shows a TW3004AR connected to a UTP Spectra ® dome for Coaxitron PTZ control. TW3004AR POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY COAXITRON UTP VIDEO MATRIX SPECTRA VC-UTP BOARD MONITOR Figure 6.
Figure 7 shows a TW3004AR connected to a TW3001P passive transceiver. The TW3001P then connects to a non-UTP fixed camera. TW3004AR POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY UTP TW3001P MONITOR MONITOR MONITOR MONITOR DIRECT CONNECTION FIXED CAMERA Figure 7.
Figure 8 shows a TW3004AR connected to a TW3032P passive transceiver. TW3004AR POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY MONITOR MONITOR MONITOR MONITOR UTP FIXED CAMERA TW3032P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Figure 8.
Figure 9 shows a TW3004AR connected to a TW3004P passive transceiver. The TW3004P then connects to a non-UTP fixed camera. TW3004AR TW3004P POWER FROM RK5000PS-3U OR 12 VDC OR 24 VAC POWER SUPPLY UTP MONITOR MONITOR MONITOR MONITOR FIXED CAMERA Figure 9.
Specifications ELECTRICAL Input Voltage Power Consumption Wire Type Wire Category DC Loop Resistance Differential Capacitance Transient Immunity Insertion Loss 12 VDC or 24 VAC, 50/60 Hz 10 watts Unshielded twisted pair (24 AWG minimum) Cat3 or better 52 ohms per 1,000 ft (305 m) 19pF/ft max 300 W peak pulse power (8/20 US) 72 dB over; 0-8 MHz frequency range VIDEO CHARACTERISTICS Video Output Format Frequency Response Common Mode/Differential Mode Rejection 4, BNC NTSC, PAL, SECAM DC to MHz >70 dB MECH
C1667M (6/06)
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.