I N S T A L L A T I O N Spectra III™ EVS Pendant Back Box C2493M (12/05)
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
Installation . 1 Install the mount for the pendant dome. Refer to the instructions supplied with the mount. 2 Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull power, alarm/auxiliary, and network cable into the back box. The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.
Connect the power wires to the circuit board inside the back box. Connect any alarm and auxiliary circuits. Turn on the power to the system. The green LED on the door indicates system power is on. NOTE: Aux 1 – Maximum 2 A at low voltage (<40 V) ALARMS ALARM COM AUX1 AUX COM POWER 5 Connect a 10/100/1000BaseT network Cat5e (or better) cable to the RJ-45 network connector located inside the back box.
SW1-1 is set to the ON position. All other switches are set to the OFF position. 1 2 3 4 5 6 7 8 SW1 1 2 3 4 5 6 7 8 1 on SW2 on SW3 7 No DIP switch settings are required for the system. Before installing the dome drive verify that switch SW1-1 (SW1, switch 1) is set to the ON position and all other switches are set to the OFF position. The switches set the dome drive for Pelco’s D protocol, address 1, 2400 baud, and no termination. ON 8 Install the dome drive.
Specifications SYSTEM Processor Operating System User Interface GENERAL PowerPC® 405EP Linux® Remote operation via WS5050 or VCD5000 Construction Back Box Dome Drive Bubble Light Attenuation Smoked Clear Chrome and Gold Cable Entry (Back Box) Weight (approximate) Back Box Standard Pendant Environmental Pendant Dome Drive Lower Dome Environment Operating Temperature Standard Pendant ELECTRICAL Input Voltage Input Power Fuse Auxiliary Outputs Alarm Inputs 18-30 VAC; 24 VAC nominal 36 VA nominal (without h
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.