I N S T A L L A T I O N IP110 Series Camclosure® Integrated Camera System C3432M-G (4/09)
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Open Source Software Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Description . . . . . . . . . . . . . . .
List of Illustrations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 4 DHCP Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Endura Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Private Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Tables A B C D E F IP110 Series Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Wire Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 DN Models Switching Thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 DW Models Switching Thresholds . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 7. Only use attachments/accessories specified by the manufacturer. 8. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus. 9.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
Open Source Software Notice This product includes certain open source or other software originated from third parties that is subject to the GNU General Public License (GPL), GNU Library/Lesser General Public License (LGPL), and different and/or additional copyright licenses, disclaimers, and notices. The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer to the exact terms of the GPL and LGPL at http://www.fsf.org (Free Software Foundation) or http://www.
Description The IP110 Series Camclosure® is an indoor/outdoor, fixed mini dome system with a built-in 100Base-TX network interface for live streaming to a standard Web browser (Microsoft® Internet Explorer® or Mozilla® Firefox®). The network mini dome features open architecture connectivity for third-party software recording solutions and is also Endura Enabled™ to record, manage, configure, and view multiple live streams.
Basic System Configurations IMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact your local Pelco representative to discuss your specific requirements.
NETWORK SWITCH IP110 IF NOT DHCP, CAMERA IS ASSIGNED DEFAULT IP ADDRESS 192.168.0.20 ON NETMASK 255.255.255.0 WEB BROWSER IP110 PRIVATE NETWORK Figure 3. Private Network Example CABLE MODEM ROUTER / SWITCH (DHCP SERVER DISABLED) CAMERA 1 FIXED BUT UNIQUE IP ADDRESS, SAME SUBNET MASK AS COMPUTER NOTE: FOR A SECURE NETWORK, PELCO RECOMMENDS THE IP110 CAMERA IS PLACED BEHIND A FIREWALL.
Cover and Back Box Installation The IP110 Series Camclosure integrated camera system mounts only to a surface. It can be wired through the cover into a surface, electrical box, plaster ring, or through a side conduit opening. NOTE: A flash mount adaptor ring is available. Refer to the IP110-F Flush Mount Adaptor Installation manual (C2238M) for installation instructions. BASIC SURFACE INSTALLATION 1. Remove the two 8-32 x 0.
4S ELECTRICAL BOX INSTALLATION 1. Attach an ICS110-AP adapter plate (not supplied) to a 4S electrical box. Use two 8-32 x 0.75-inch Phillips flat head screws (supplied with both the IP110 and the adapter plate). 2. Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers to separate the cover from the back box. 3. Pull the cable and wires into the cover. 4. Attach the cover to the adapter plate with four 8-32 x 0.375-inch Phillips pan head screws (supplied with the adapter plate).
404 PLASTER RING INSTALLATION 1. Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers (supplied) to separate the cover from the back box. 2. Pull the cable and wires into the cover. Use three 6-32 x 0.75-inch Phillips pan head screws (supplied) or two 8-32 x 0.75-inch Phillips pan head screws (supplied) to attach the cover to an installed 404 plaster ring. Use stainless steel hardware when installing the system outdoors. 3.
SIDE CONDUIT INSTALLATION 1. Remove the two 8-32 x 0.375-inch Phillips pan head screws and washers (supplied) to separate the cover from the back box. 2. Remove the conduit plug from the cover. Install a 0.75-inch (1.91 cm) threaded conduit connector (not supplied) into the conduit hole in the cover. 3. Attach the cover to the mounting surface (hardware not supplied). Use stainless steel hardware when installing the system outdoors. 4.
Wiring Tables CAT5 CABLE Connect a Cat5 cable to the RJ-45 network connector. The 8-pin connector includes video and PoE for the camera. PoE (IEEE 802.3af) injects power over the same cabling that carries the network data, eliminating the need for a separate power supply. This simplifies the installation and operation of the camera without any degradation of network performance. NOTE: The IP110 Camclosure will autosense and work with either a cross over cable or straight cable.
ALARM AND 24 VAC WIRES Table B. Wire Descriptions Wire Color Description Black 24 VAC (use only if PoE is not connected) Red 24 VAC (use only if PoE is not connected) Blue Alarm In Blue/White Alarm In, Return Green Relay Out Green/White Relay Out, Return CONNECTING A RELAY DEVICE The IP110 Camclosure has an output for triggering an external device. It supports both momentary and continuous relay operation.
CONNECTING ALARMS The IP110 Camclosure provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally closed devices are supported. The IP110 Series Camclosure supports supervised and unsupervised alarms. Figure 11 shows how to wire the IP110 Camclosure to an alarm. ALARM RETURN: BLACK / WHITE WIRE ALARM: BLACK WIRE Figure 11. Unsupervised Alarm Input Wiring NOTE: The black wire is internally connected to the Camclosure chassis.
Camera Module The IP110 Series Camclosure camera module includes the camera, camera bracket, and heater board. To perform most camera adjustments, you must remove the module from the back box. Use the following instructions to install or remove the camera module. WARNING: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models. CAMERA ORIENTATION The camera module is configured for ceiling mounting at the factory.
MODULE INSTALLATION To install the camera module into the back box: 1. Plug the camera (10-pin), heater board (4-pin), and service (3-pin) connectors into the back box (refer to Figure 13). HEATER CONNECTOR SERVICE CONNECTOR CAMERA CONNECTOR Figure 13. Back Box Connectors 2. Make sure the tabs on the camera bracket and the service connector are pointing out of the enclosure and away from the ceiling or wall. 3.
Camera Adjustments To perform camera adjustments: 1. Make sure the camera and service connectors are connected to the board inside the back box. You may have to remove the camera module from the back box. 2. Connect a monitor to the service connector (refer to Service Connector on page 32). Turn on the monitor. 3. Turn on the camera.
VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS NOTE: You will need a miniature Phillips or flat-tip screwdriver to loosen and tighten the locking screws. To adjust the field of view: 1. Loosen the zoom locking screw (refer to Figure 15). 2. Turn the zoom adjustment ring clockwise or counterclockwise to select the field of view. 3. Tighten the zoom locking screw. FOCUS ZOOM Figure 15.
To adjust the focus: 1. Loosen the focus locking screw. 2. Position the inverted dome approximately 0.125 inch (3.175 mm) from the front of the lens. Make sure that the lens and the dome are centered (refer to Figure 16). 3. Turn the focus locking screw clockwise or counterclockwise to adjust the focus. 4. When the optimal focus is reached, tighten the focus locking screw. ZOOM FOCUS 0.125 INCH (3.175 mm) CENTER BUBBLE WITH LENS Figure 16.
DN/CH SERIES ADJUSTMENTS Refer to Figure 17 to adjust the IP110-DN or IP110-CH model. Figure 17. Adjusting the IP110-DN/CH Series Camclosure SWITCH SETTINGS Locate the DIP switch. Then set the switches for your installation. SW4-1: Auto Gain Control The automatic gain control (AGC) adjusts the image automatically to compensate for changes in light levels. Set SW4-1 to ON to enable AGC. Set it to OFF to disable AGC. The default setting is ON.
SW4-4: Flickerless In certain lighting conditions, a flicker in the light source may affect camera operation. Flickering can be caused by a number of conditions, including the quality of the source power and the age and type of fluorescent bulbs and ballasts. Set SW4-4 to ON to enable flickerless operation. The camera will remove the effects of flickering when present. The shutter speed will be set to 1/120 (NTSC) or 1/100 (PAL). Set it to OFF to disable flickerless operation. This is the default setting.
DAY/NIGHT OPERATION NOTE: This section only applies to DN model cameras. DN model cameras regularly check the brightness level of the field of view to determine when to switch between day (color) and night (black-white) operation. Actual brightness threshold levels are affected by camera angle, amount of zoom, field of view, lens, and type of lighting. The switching process lasts from seven to 10 seconds. RISING LIGHT LEVEL COLOR MODE 1.5 lux B-W MODE COLOR MODE 3.
DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS Refer to Figure 19 to adjust the IP110-DW or IP110-CW model. SW1 DEFAULT SWITCH POSITION R7 Figure 19. Adjusting the IP110-DW/CW Series Camclosure SWITCH SETTINGS Locate the DIP switch. Then set the switches for your installation. SW1-1: Video Format Set SW1-1 to ON for NTSC. Set it to OFF for PAL. The default setting is ON. SW1-2: N/A SW1-3: Interlaced Scanning/Progressive Scanning Interlaced scanning is the standard for analog recording installations.
SW1-4: Auto White Balance/Manual White Balance Auto white balance (AWB) is enabled by default (ON). To manually set and lock the white balance: 1. Set SW1-4 to ON. 2. Hold a white background in front of the lens until the video shows all white. 3. While holding the background in place, set SW1-4 to OFF. A green block and a white block alternate briefly on the video image until the manual white balance (MWB) process is complete.
B-W MODE B-W MODE 4.0 lux DARK RISING LIGHT LEVEL COLOR MODE FALLING LIGHT LEVEL 7.0 lux B-W MODE 1.0 lux B-W MODE 3.0 lux RISING LIGHT LEVEL COLOR MODE COLOR MODE FALLING LIGHT LEVEL COLOR MODE Figure 18 and Table D show how the camera switches between color and black-white operation for each setting. DUSK Figure 20. DW Models Threshold Switching Levels Table D. DW Models Switching Thresholds Dark (ON) Dusk (OFF) Color to B-W 1.0 lux 4.0 lux B-W to Color 3.0 lux 7.
Camera Positioning Manually rotate and tilt the camera module to position the camera, and then tighten the tilt screws (axis 1 in Figure 21). NOTE: Do not over-rotate the module. Excessively turning the module in one direction could result in damage to the wiring. ì Tilt 80° (20° to 100°) î Pan 360° ï Rotation 360° Figure 21.
Install Dome and Trim Ring 1. To adjust the dome liner (refer to Figure 22): a. Align the screw holes in the trim ring with those in the back box to identify the proper dome liner position. b. Loosen the three Phillips screws located in the trim ring. c. Insert the blade of a standard screwdriver in one of the adjustment grooves. Rotate the dome liner to position the viewing window over the camera lens. d. Tighten the three Phillips screws to lock the dome liner in place.
Service Connector The IP110 Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it at the installation site to set up the field of view and focus the camera. SERVICE CONNECTOR Figure 23. Service Connector Pelco offers two optional items (CST150 and ICS-SC) that plug directly into the service connector. Before using either option, you must loosen the tamper-resistant screws to remove the trim ring from the back box.
d. Solder the center connector of the cable to the center pin of the plug. e. Thread the braid of the cable through the hole in the crimp pin. f. Solder the braid to the top of the crimp pin. g. Crimp the end of the crimp pin around the cable. h. Reassemble the support sleeve and the plug. CENTER CONDUCTOR COAXIAL CABLE BRAID (SHIELD) 2.5 MM MONAURAL HEADPHONE PLUG Figure 24. Attaching the 2.
Reset Button Use the reset button located on the board inside the back box to access the following modes described in Table E. Table E. Reset Button Modes and Descriptions Mode Function Unit Status Indicator Light Configuration Starts the reset LED selection sequence. Flashes green. Reboot Restarts the unit. Flashes green and red simultaneously, when entering this mode. The LED then flashes green when mode is selected and during the reboot.
Troubleshooting If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. You should have the serial number from the product label available. Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and repairs to qualified technical personnel. Exchange the defective unit and return it for repair. Table F.
Table F. Troubleshooting the IP110 Series (2 of 3) 36 Problem Possible Cause Suggested Remedy Image too light Installation error • Check DIP switch settings. • Use a service connector to check camera operation. Connect one end of the service connector to the service connector input inside the back box. Then connect the other end of the service connector to a monitor. • Replace camera module with new camera. Image only displayed in black and white Color level setting • Check DIP switch settings.
Table F. Troubleshooting the IP110 Series (3 of 3) Problem Possible Cause Suggested Remedy Network not working Faulty cable connection Check all cable connections and ensure all plugs are properly plugged in. Incorrect serial device configuration A hub will not work with the available network bandwidth shared across all ports. Use a Fast Ethernet switch, Gigabit Ethernet switch, or a cable modem router with an n-Port switch. Network connectivity issues Contact your network administrator.
Specifications GENERAL Pan/Tilt Adjustment Pan Tilt Rotation Construction Impact Cable Entry Finish Light Attenuation Smoked Clear Unit Weight Manual 360° 80° (20° to 100° range) 360° Aluminum with steel camera mounting bracket and polycarbonate dome IP110 is a rugged product that exceeds an IK10++ rating of Standard EN62262 and can withstand up to 100J in a vertical impact One 0.75-inch (1.91 cm) NPT threaded opening on side; two 0.75-inch (1.91 cm) openings on NEMA cover Gray polyester powder coat f/1.
VIDEO Signal System Compression Video Streams Video Resolutions 4CIF 2CIF CIF QCIF Bit Rate Configurable Video Access form Web Browser Users Minimum Web Browser Requirements RAM Ethernet Card Web Browser Screen Resolution NTSC or PAL MPEG-4, MJPEG in Web viewing mode 3, simultaneous NTSC PAL 704 x 480 704 x 576 704 x 240 704 x 288 352 x 240 352 x 288 176 x 120 176 x 144 20 kbps to 2 Mbps per stream, implements EnduraView™ Camera live view for up to 10 video sources 10 simultaneous users, unlimited number o
LENS Type Focal Length Format Size Operation Iris Focus Zoom Varifocal with auto iris 3.0~9.5 mm 9.0~22.0 mm 1/3-inch Auto (DC drive) Manual Manual (Design and product specifications subject to change without notice.) Ø 5.50 (13.97) 3.63 (9.22) 3.03 (7.70) 5.28 (13.41) Ø 3.79 (9.63) NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
C3432M-G (4/09) 41
REVISION HISTORY Manual # C3432M C3432M-A C3432M-B C3434M-C C3432M-D C3432M-E C3432M-F C3432M-G Date 3/07 5/07 8/07 11/07 1/08 4/08 6/08 4/09 Comments Original version. Cable harnesses modified per ECO 07-17470. Added picture elements to specifications. Added FCC Class B and revised DIP switch setting adjustments. Revised figures 20 and 22. Added Open Source Software Notice. Removed references to JRE per CN21186. Changed static IP address to new default 192.168.0.20 per CN21529.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
www.pelco.com Pelco, Inc.