I N S T A L L A T I O N ExSite™ Series Explosionproof Power Module IPSXM-2 and IPSXM-7 C313M-D (8/05)
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Install the Power Module . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the supply circuit before opening. Keep assembly tightly closed when in operation. 7. The maximum ambient temperature range is -76°F to 140°F (-60°C to 60°C). 8.
Getting Started Thank you for purchasing Pelco’s ExSite™ Series explosionproof integrated positioning system. This manual includes instructions for installing the power module for the ExSite Series system. For complete system installation instructions refer to the installation manual placed in the pan and tilt box. DANGER: Do not connect the power module to a supply circuit unless all ExSite system components (pan and tilt, camera module and power module) are installed.
Install the Power Module Attach the power module to the mounting surface. Use only installation methods and materials capable of supporting four times the maximum specified load of the system (220 lb/100 kg). NOTE: If required, install the optional TXB translator, fiber module, or UTP board before installing the power module. Refer to the installation instructions supplied with the TXB translator, fiber module, or UTP board for installation instructions.
Connect Wiring Refer to the following information to connect the wires and cables as required. WARNING: When installing this unit, provide access to the communication wires (TX- and TX+) to allow connection to the system for future software upgrades. Connectors must be installed so that the integrity of the hazardous location is maintained. These communication wires are required even if the system uses Coaxitron® control. Maximum wire distance for RS-422 data wires is 4,000 ft (1,219 m).
DIP Switch Settings Configure the receiver address, termination, and baud setting for the system. The DIP switches to configure these settings are located on the top of the power module. NOTE: No DIP switch settings are required for Coaxitron® control. Figure 3 shows the default settings for the DIP switches. Refer to the following to configure the ExSite system settings. SW1-1 is set to the ON position. All other switches are set to the OFF position.
Tables Table A.
Table B.
Table B.
Table B.
Specifications ELECTRICAL Input Voltage 24 VAC or 100-240 VAC Input Voltage Range ±10% Power Consumption Maximum 60 watts (120 VA) per system Electrical Connections 6-foot wire harness with connections for power, video, data control, alarm inputs, and auxiliary outputs MECHANICAL Cable Entry One 0.75-inch (1.91 cm) NPT threaded opening Pan Movement 360° continuous pan rotation Vertical Tilt Unobstructed +90° to -90° Variable Pan/Tilt Speed Pan Tilt 0.1° to 40°/sec variable-speed operation 0.
C313M-D (8/05)
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.