User's Manual

C665M-C (5/03) 13
3 END TIME - Program the time to stop recording. If you want GROUP 1 to stop recording at 5:30 in the evening, use the
arrow keys and set the END TIME to
4 CLEAR ALL SCHEDULE – Clears all group schedules.
FULL RECORD – Configures Group 1 to record continuously all enabled cameras twenty-four hours, seven days a week.
SENSOR TO CAMERA – Automatically selects the camera sensor for a group schedule in a one-to-one ratio (Camera 1,
Sensor 1, Group 1).
5 DAY OF WEEK – Select the days of the week a group schedule will record.
6 REMOTE ALARM – Check the remote alarm box to notify a remote site when an alarm is set off.
TARGET IP ADDRESS – Input the address of the remote site to alert when an alarm is set off.
NOTE: The Emergency Agent software must be loaded on the remote site PC for the remote alarm function to work.
Refer to the
Emergency Agent Software
section of this manual for more information.
7 AUTO REBOOT – Set the day and time the system will reboot automatically. Pelco recommends that the DX7000 be
programmed to reboot weekly. The system will momentarily be unavailable during the reboot; recording and playback
functions will not be operational.
8 CAMERA, MOTION, SENSOR, AND RELAY Buttons – Select the cameras, recording triggers, and relay outputs for the
group schedule.
9 GROUP INFORMATION – Lists schedule conflicts between groups.
2 START TIME – Program the time to start recording. If you want GROUP 1 to start recording at 6:30 in the morning, use the
arrow keys and set the START TIME to