ECP190 / ECP290 DOOR CONTROLLERS STAND ALONE ACCESS CONTROL Site Coded & Sequentially Numbered Access Passes for Security, Identification & Operational Integrity. ® nacd.co.
contents ECP190 ECP190 / ECP290 / ECP290 DOOR DOORCONTROLLERS CONTROLLERS Explanation of Noralsy ® Access Passes 3 General Door Controller Information 4 ECP 190 Door Controller schematic 5 ECP 290 Door Controller schematic 6 How to use the Telpro™ programmer 7-8 Programming Set-up on installation 9-10 Block loading of Access Passes 10 Deleting individual Access Passes 10-11 Validating individual Access Passes 11 Block deletion of Access Passes 11 Changing lock output time 11 Changing
NORALSY® ACCESS PASSES ALL ACCESS PASSES ARE VISIBLY NUMBERED Numbered The number of each and every Access Pass is visible. Just by looking at it, you know which Access Pass you have. Noralsy® pre-number each Access Pass because this is the only way you can know for sure what you have received, what you need to program the system to accept (or, reject in the case of loss, theft or non-return) and, who has been issued with which TELBIP Access Pass.
Noralsy ECP Door Controllers ® IMPORTANT –If NOT Monitoring Door Open/Closed Status OR ECP ALARM BUZZES CONTINUOUSLY ELEC/INST/800 6 5 4 3 2 1 ON 6 5 4 3 2 1 1 ECP Door Controller Standardisation of Terminal Numbering Place Noralsy unit on a flat surface with PCB facing skywards. View terminal blocks from the outside looking in. Terminal No. 1 is always the first on the left of every terminal block strip.
ECP190 Door Controller for 1 n0 Door/Access Point ■ Capacity 999 Users ® ELEC/INST/801 ECP 190 Door Controller 3 2 1 3 2 1 2 1 (—) (+) Supply 12V DC ± 10% Dimensions 103 L x 106 W x 83 D (6 DIN units) Weight 0.44 Kg Power Consumption 55mA quiescent CE Norms EN50082, EN55022 Class B 3 2 1 2 1 1 5 2 4 3 3 4 2 5 1 1 1 2 3 4 5 6 ON 1 2 3 4 5 6 = = 1 2 3 4 5 6 If not used, link terminals 3 & 4 to create a permanently closed circuit.
ECP290 Door Controller for 2n0 Doors/Access Points ■ Capacity 999 Users per door ® ELEC/INST/830 ANTI-PASSBACK FEATURE AVAILABLE ECP 290 Door Controller * If not used, link terminals 3 & 4 to create a permanently closed circuit. 6 Supply 12V DC ± 10% Dimensions 163 L x 106 W x 83 D (10 DIN units) Weight 0.
Programming Stand-Alone Access Control Systems using TELPRO™ Programmer. ® TELPRO™ PROGRAMMER Access Control Modules with integral Infra-Red The TELPRO™ Programmer is a handheld keypad used for programming Noralsy® stand-alone access control systems. MLP3 Proximity The TELPRO™ Programmer can be used as a wirefree infra-red programmer. Simply point at the reader/receiver module to program. Installation companies only ever need 1no. TELPRO™ Programmer.
Programming using TELPRO™ as a remote wire-free programmer. Remote Programming Range: Infra-Red Receiver Proximity Reader 20 cms - 5 metres 5 cms - 10 cms How to use the TELPRO: Important: Each press of a button is confirmed (as received) by the reader/receiver by a single beep. Press the TELPRO™ buttons gently. Flick TELPRO switch to ON - Red LED on the right must light up. (Remember to turn unit off when finished) Dimensions (mm): 120L x 60W x 25D Point TELPRO at the reader/receiver.
ECP Door Controller with ACCESS PASS CONTROL PROGRAMMING TOP POINTS TO REMEMBER ■ Programming is effected via the TELPRO programming keypad. ■ ■ Site Code is always a 5 digit number. Site Code is always stored in Slot No. 01. ■ ■ Master Code (Programming Access Code) is always a 5 digit number. Master Code is always stored in Slot No. 06. TIP - WHEN YOU ARE PROGRAMMING It is a good idea to have written down in advance what you want to program. Enter the numbers in quick succession after a beep.
STEP 4 You must now inform the Door Controller of the Site Code of the Access Passes supplied. The Site Code is always stored in Slot No. 01. The Site Code is always a 5 digit number. Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you the Site Code of the Access Passes delivered. * Example: Site Code = 45801 After a beep enter on the TELPRO: A sharp beep confirms that you have correctly entered the Site Code. Programming mode beep - every 4 seconds resumes.
After a beep enter on the TELPRO: A sharp beep confirms that you have correctly deleted Holder Number 074. Programming mode beep - every 4 seconds - resumes. Example C: Validation of 1no. Access Pass You have just received the additional Access Pass ordered for Alan Jones who had lost his earlier in the week. The last 3no. digits on the Access Pass are 176. Alan Jones is now Holder Number 176 and you have to program the system to accept Holder Number 176. Enter the Master Code 19388 on the TELPRO.
ECP290 DOOR CONTROLLER INFORMATION FOR 2 DOORS – IMPORTANT FLICKING PROGRAMMING SWITCH SW1. The access control readers on both doors will start to beep every 4 seconds indicating programming mode status. Only 1 no. access point (door) can be programmed at a time. IF USING THE TELPRO PROGRAMMER IN WIREFREE INFRA-RED MODE: Simply point at the relevant reader to effect programming for its related access point (door). Repeat the process for the 2nd access control reader on the ECP290.
Mode 4 - Dual Security, Access Pass + Keypad Code 00400508 = Set-Up, Mode 4 È Relay output time in seconds User required to present a valid access pass and then enter a valid code or vice versa in order to gain access. A maximum of 27no. 5 digit keypad codes can be set at any one time. Any 1no. of these keypad codes together with a valid access pass is sufficient to gain entry. This feature is also available on the ECP190 Door Controller.
Noralsy® ECP Door Controller ® Fail Safe Locking + 3 2 1 3 2 1 2 1 (—) (+) ELEC/INST/802 ECP190 Door Controller Automation Control / Volt Free 3 2 1 3 2 1 2 1 ELEC/INST/803 ECP190 Door Controller Entrance/Exit Access point requiring access control on both sides of the door, gate or barrier. ie. Access Pass to be presented to enter and again to exit through the same control point.
Noralsy® ECP Door Controller ® Locking 3 2 1 3 2 1 ECP190 Door Controller 2 1 (–) (+) ELEC/INST/805 DIN Rail Mounting DIN Rail ELEC/INST/806 Wall Mounting ELEC/INST/807 15
Noralsy® DIN Rail Power Supplies ® ARE121 12V AC/DC 1 AMP MAXIMUM OUTPUT ARE122 12V DC 2 AMP MAXIMUM OUTPUT ELEC/INST/808 ELEC/INST/809 ARS122 12V DC 2 AMP MAXIMUM OUTPUT AB126 BATTERY STANDBY ELEC/INST/811 ELEC/INST/810 16
Noralsy® Powering ECP Door Controller(s) using Noralsy® DIN Rail Power Supply Units ® ARE121 + ECP190 ELEC/INST/812 ARE122 + ECP290 ELEC/INST/812A 17
ECP190 DOOR CONTROLLER with KEYPAD ACCESS CODE CONTROL TOP POINTS TO REMEMBER ■ Programming is effected directly via the keypad. ■ ■ Master Code (Programming Access Code) is always a 5 digit number. Master Code is always stored in Slot No. 06. ■ ■ Keypad Access Codes are always 5 digit numbers. Keypad Access Codes can be stored in Slot Nos. 03 - 05 and 07 - 30 only. SET-UP ON INSTALLATION Proceed exactly as detailed before in section ECP Door Controller with Access Pass Control.
After a beep enter on the keypad: A sharp beep confirms that you have deleted Alan’s code. Programming mode beep - every 4 seconds - resumes. After a beep enter on the keypad: A sharp beep confirms that you have deleted Alex’s code. Programming mode beep - every 4 seconds - resumes. Note 1. You do not need to know the actual code itself which needs to be deleted, only the Slot Number in which it is stored. Note 2. Capacity is never reduced as a result of deleting codes.
ARE122 POWER SUPPLY ECP 190 DOOR CONTROLLER Supply 12V DC ±10% Dimensions 103 L x 106 W x 83 D (6 DIN units) Input 85VAC - 264VAC Output 12V DC - 2AMP Dimensions 160 L x 106 W x 85 D (10 DIN units) Weight 0.44 Kg Power Consumption 55mA quiescent CE Norms EN50082, EN55022 Class B Weight 0.