Installation Manual

33
Network
Interface 2 Gigabit Ethernet RJ-45 port (1000Base-T)
Front Panel
Buttons
Indicator
Unit Status Green, amber, red
Primary Network Green, amber, red
Secondary Network Green, amber, red
Software Status Green, amber, red (based on diagnostics)
Hard Disk Status Green, red, off (behind bezel)
Power
Power Input 100 to 240 VAC, 50/60 Hz, autoranging
Power Supply Internal
Power Consumption Operating Maximum
100 VAC 160 W, 1.60 A, 547 BTU/H
115 VAC 160 W, 1.39 A, 547 BTU/H
220 VAC 160 W, 0.72 A, 547 BTU/H
Environmental
Operating Temperature 10° to 35°C (50° to 95°F) at unit air intake (front of unit)
Storage Temperature –40° to 65°C (–40° to 149°F)
Operating Humidity 20% to 80%, noncondensing
Maximum Humidity Gradient 10% per hour
Operating Altitude –15 to 3,048 m (–50 to 10,000 ft)
Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configura-
tion, floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature
at the unit is continuously within the operating temperature range.
Physical
Construction Steel cabinet
Finish
Front Panel Gray metallic with black end caps
Chassis Black matte finish
Dimensions 50.8 x 43.4 x 8.9 cm (20" D x 17.1" W x 3.5" H)
Mounting Desktop (feet) or rack (2 RU per unit)
Unit Weight 13.06 kg (28.8 lb)