Table AA. Relay Settings
Setting Description Default Setting
Relays
Displays the number (default) or name of the relay. The entry highlighted in this box is
directly associated with the physical output number displayed in Physical output. By
default, the relay outputs displayed are numbered 1–4. The default entries in the Relays
pane are 01–16. When an entry is selected in the Alarms pane, the same entry is
displayed in the Modify Alarm area’s Name text box.
Relay array outputs are supported as follows:
4 or 8 channels have two relays
16 channels have four relays
Select relay
Relay name Displays the relay number or name. You can modify the entry displayed in this text box.
No default
setting
Physical output
The number of the physical connector to which the relay out is connected. This number
cannot be modified.
0
Mode
This list allows you to select the following relay mode options:
•Off
On (default)
Toggle
•Pulse
Off
Period
Sets the relay period. This setting defines the total time in tenths of a second (5–1,000) for
the relay control pulse.
5
On state
Sets the percentage of time during the defined period that the relay will be in the ON
state.
0
Number of pulses
Sets the number of times (0–99) the relay is pulsed (that is, placed in the ON state) during
the defined period.
0
Table AB. Sequence Monitor Settings (1 of 2)
Setting Description Default Setting
Default dwell time
Sets the global dwell time (in seconds) that video from each selected camera is
displayed on the sequence monitor.
10 seconds
Interleave video on alarm
When selected, causes alarm video to be interleaved with normal video displayed on the
sequence monitor.
Disabled
Select cameras to add to sequence
Available Cameras
Lists available cameras that can be added to the sequence. To add cameras to the
“Cameras in the sequence” list, select a camera in the Available Cameras list, and then
select Add. To remove cameras from the list, select a camera in the “Cameras in the
Sequence” list, and then select Remove.
No default setting
Add/Remove
Command buttons that let you add or delete cameras from the “Cameras in the
sequence” list.
N/A
Cameras in the sequence List of cameras that are displayed on the sequence monitor. No default setting