Spec Sheet
TECHNICAL SPECIFICATIONS
ELECTRICAL
Ethernet Port Inline RJ-45 for 100Base-TX, auto MDI/MDI-X
Ethernet Cabling Required Cat5 or better for 100Base-TX
Input Power 24/120/230 VAC, 50/60 Hz, switch selectable
for 120/230 VAC
Input Power Range +15%/–20%
Power Consumption Lens Power
14.25, 30, 50 mm 4.0 A, 120 VA (110 W)
100 mm 5.5 A, 160 VA (130 W)
24 VAC Fuse 6.3 A, slow-blow
120/230 VAC Fuse 2 A, slow-blow
Heater Thermostat controlled
Local Storage Micro SD
Alarm Inputs N.O. switch, N.C. switch, or 1 kohm;
supervised
Mechanical Relay Output* Voltage Current Power
60 VDC, 125 VAC 1 A 62.5 VA, 30 W
Solid-State Relay Output* 60 V 600 mA (N/A)
Audio
Maximum Input Level 1 VRMS
Input Impedance 600 ohms, differential
Cable Type unsheilded twisted pair (UTP)
Optional Active
Microphone Power 12 VDC, 10 mA maximum
Serial Control Port 4-wire, RS-422/RS-485 (Pelco D or Pelco P)
Serial Control Cabling Type UTP
MECHANICAL
Pan Movement 360° continuous pan rotation
Vertical Tilt 33° to –79° unobstructed from horizontal
Variable Pan/Tilt Speed Analog Control IP Control
Pan 0.5° to 40°/sec
0.1° to 100°/sec
100°/sec turbo
Tilt 0.5° to 20°/sec 0.1° to 30°/sec
Preset Speeds
Pan 100° per second
Tilt 30° per second
Latching 2 captivated Torx
™
screws
Face Plate 4 Torx screws
Cable Entry 2 adjustable 0.5-inch NPT liquid-tight glands
*Assumes maximum operating capacity.
GENERAL
Construction Aluminum
Finish Gray polyester powder coat
Environment Indoor/outdoor
Operating Temperature –40° to 50°C (–40° to 122°F)
Storage Temperature –40° to 60°C (–40° to 140°F)
RECOMMENDED MOUNTS AND ADAPTERS
ECM100 Corner mount adapter for use with EWM wall
mount
EPM Pole mount adapter for use with EWM wall
mount
EA4348 EWM-to-Legacy adapter; use with PP4348
parapet mount
PM2000/PM2010 Pedestal mount with cable feedthrough; for
use with Esprit systems with EPP pedestal
adapter plate
RECOMMENDED POWER SUPPLY
MCS Series Multiple 24 VAC camera power supply, indoor
WCS Series Single/multiple 24 VAC camera power supply,
outdoor
CERTIFICATIONS/RATINGS/PATENTS
• CE, Class A
†
• FCC, Class A
†
• UL/cUL Listed
†
• C-Tick
†
• Meets NEMA Type 4 and IP66 standards
†
• Shock and Vibration, Meets NEMA TS 2; IEC613736-8, -9, -10
†
• Patents
†
†
As of the date of this publication, these items are pending. Please
consult the factory, our Web site at
www.pelco.com
, or the most
recent B.O.S.S.
®
update for the current status of certifications.