® EU3512-3X Environmental Enclosure and Light Duty Wall Mount Installation/ Operation Manual C2428M-A (2/01) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................ 3 DESCRIPTION ................................................................................................................... 4 INSTALLATION ................................................................................................................... 4 INSTALL WALL MOUNT ............................................................................................
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 , or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
DESCRIPTION The EU3512-3X is an indoor/outdoor light-duty camera enclosure and light-duty wall mount. The enclosure includes a sun shroud and 230 VAC heater and defroster. The wall mount has an adjustable tilt table allowing for mechanical positioning of the enclosure. Install the EU3512-3X to any wall or vertical surface, capable of supporting up to 20 pounds (9 kg). INSTALLATION INSTALL WALL MOUNT Perform the following steps to install the mount: 1. Determine the mounting location.
CAMERA AND LENS INSTALLATION 1. To install the camera and lens onto the enclosure sled: a. Extend the lens to the maximum length. b. Position the camera and lens so that they do not extend beyond the track. c. Fasten the camera and lens to the sled with the two, 1/4-20 x .375 Phillips screws supplied. The edges of the sled are bent, one side up and the other side down. One side of the sled has a wide lip and the other side has a narrow lip.
Table B. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Wire Gauge 20 EXAMPLE: An enclosure that requires 80 vA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge of 20 Awg.
SPECIFICATIONS ENCLOSURE Camera Mounting: Multiple holes on adjustable camera sled; camera sled mounts in threaded strip for easier removal and can be inverted for additional camera elevation. Camera and Lens Size: Accommodates camera and lens combinations (including BNC connector) 2.87 (W) x 3.00 (H) x 9.00 (L) inches (7.28 x 7.62 x 22.86 cm) Viewing Window: Lexan®, .187-inch (4.75 mm) thick, optically clear, impact-resistant, MR5 coated (U.L. 94HB rated). Viewing Area: 2.25 (H) x 2.63 (W) inches (5.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard).