I N S T A L L A T I O N Sarix Enhanced III Dome Cameras Dome (IME Series) Models C6644M (2/20)
C6644M (2/20)
Contents Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Important Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Regulatory Notices (FCC Class A). . . . . . . . . . . .
C6644M (2/20)
Important Notices REGULATORY NOTICES (FCC CLASS A) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules.
POWER SOURCE This product is intended to be supplied by a Listed Power Adapter or DC power source marked “L.P.S.” (or “Limited Power Source”), rated 12Vdc, 2A, 24Vac (50/60 Hz), 1.5A or POE 56Vdc, 0.6A, Tma = 60 degree C, and the altitude of operation = 2000m. If you need further assistance with purchasing the power source, please contact to PELCO, INC for further information. KOREAN CLASS A EMC ESD WARNING WARNING: This product is sensitive to Electrostatic Discharge (ESD).
C6644M (2/20) 7
Description The Sarix Enhanced IME Series dome cameras include indoor and environmental domes. All environmental models feature a robust design that is IK10+ (50 Joules) rated and vandal resistant. The environmental models feature worry-free use in harsh environments with IP66, IP67, IP68, and Type 4X ratings, and a wide range of operating temperatures. Indoor models are rated to IK10 (20 Joules) and IP66.
SYSTEM MODEL NUMBERS Back Box Resolution Surface Lens Model Number 2 MP 2.8 to 8 mm IME238-1ERS Sarix Enhanced Environmental IR Dome Description 2 MP 2.8 to 8 mm IME238-1IRS Sarix Enhanced Indoor IR Dome 3 MP 8 to 20 mm IME332-1ERS Sarix Enhanced Environmental IR Dome 3 MP 8 to 20 mm IME332-1IRS Sarix Enhanced Indoor IR Dome 3 MP 2.8 to 8 mm IME338-1ERS Sarix Enhanced Environmental IR Dome 3 MP 2.
Dome Camera Models SUPPLIED PARTS LIST Qty 1 1 1 1 1 2 2 1 1 1 Description Camera Surface mounting template Installation manual China RoHS document Power terminal block Plastic expansion anchors M4 x 35 mm self-tapping Phillips screws Torx T20 security L-key Grommet Important Safety Instructions document USER-SUPPLIED PARTS LIST In addition to the standard tools and cables required for a video security installation, you will need to provide the following items: Qty 1 1 1 1 1 1 1 1 1 Description Conduit (
Product Overview Figure 1. Sarix Enhanced IME Series Dome Camera 1. Power Connector: A two-pin connector for 12 VDC or 24 VAC. 2. RJ-45 Network Port: Connects the camera to the IP network. also supplies power to the camera (POE+), through the same connector. (Note: To purchase a power supply, please contact Pelco for further information.) a. Green LED: With solid green, the LED indicates a live connection is established. b.
Conduit Plug Options It is recommended to use conduit when possible for cable entry into the housing. The Sarix IME Series camera comes with two conduit openings (side and top entry). Only one entry is intended to be used. the other entry must be blocked with the conduit plug (supplied). Alternatively, a grommet is supplied for cable entry through the top conduit opening when it is not possible to use the conduit.
Installation INSTALLING THE CAMERA You can install the Sarix IME Series dome cameras to a solid surface (wall or ceiling) out of the box. Additionally, the following installation methods can be used with the compatible Pelco mounts (not supplied): • Installation on a wall or a fixed ceiling. Refer to Surface Mount: Installation to a wall/ceiling or to an outlet box with IME3EBAP-E (not supplied). • Installation in a suspended ceiling or a fixed ceiling.
IN-CEILING INSTALLATION: WITH IME3ICM-E (NOT SUPPLIED) PARTS LIST SUPPLIED WITH THE MOUNT Qty 1 1 2 1 Description In-Ceiling mount Ceiling template M4 x 8 mm Phillips screws Trim ring 1. Secure the back box to the in-ceiling mounting bracket with the M4 screws (supplied). NOTE: When mounting the backbox, be mindful of the location of the microphone (See Figure 1) so that it is pointed towards areas of interest. Figure 6. Attaching the Back Box to the In-Ceiling Mounting Bracket 2.
Figure 7. Ceiling Bracket Rotation 9. Refer to Connecting the Cables, Positioning the camera, and Completing the Camera Installation sections before proceeding.
PENDANT INSTALLATION WITH IME3PM-E (NOT SUPPLIED) AND WMVE-SW (NOT SUPPLIED) PARTS LIST SUPPLIED WITH THE MOUNT Qty Description 1 Pendant cap 2 M4 x 20 mm Phillips screws INSTALLATION GUIDE The pendant cap can be installed to 1-1/2” NPT pipe or a 1-1/2” NPT wall mount arm like the WMVE-SW (not supplied). Cabling should be pulled through the pipe or wall mount arm prior to attaching the pendant cap to it. 10. Apply grease or Teflon tape to the pendant threads. CAUTION: Threads may be sharp.
SURFACE MOUNT: INSTALLATION TO A WALL/CEILING 1. Use the supplied surface mounting template to mark the position of the mounting holes, and if using the top conduit entry, mark the cable feed-through hole. NOTE: If not using conduit for the top entry hole, the grommet must be used to maintain ingress protection. NOTE: When mounting the backbox, be mindful of the location of the microphone (See Figure 1) so that it is pointed toward areas of interest. 2. Attach the backbox to the surface: a.
SURFACE MOUNT INSTALLATION TO AN OUTLET BOX WITH IME3EBAP-E (NOT SUPPLIED) INSTALLATION GUIDE PARTS LIST SUPPLIED WITH THE MOUNT Qty 1 2 2 4 Description Electrical Adapter Plate M4x16mm Phillips screws 8-32x1in Phillips screws 6-32x1in Phillips screws 1. Attach the Electrical Adapter Plate to: a. Single Gang Electrical Box using two 6-32x1in screws (supplied). b. Double Gang Electrical Box using four 6-32x1in screws (supplied). c. 4” Square Outlet Box using two 8-32x1in screws (supplied). Figure 9.
Connecting the Cables If previously removed, reinstall the camera module by screwing it into the backbox. The I/O interfaces will be seen on the front of the camera module. Make the appropriate cable connections. ETHERNET WIRING REQUIREMENT FOR POE+ Connect a Cast5e cable or higher cable (not supplied) to the RJ-45 network connector. the 8-pin port includes video over Ethernet, and PoE+ for the camera.
Alarm/Relay/Audio Port Alarm Input Alarm Output Designation Function AI Alarm In + GND Ground GND Ground AO Alarm Out + COM Common Audio In + Audio In Audio In Audio Out + Audio Out Audio Out - Figure 12. Relay and Alarm Connections POSITIONING THE CAMERA 20 • Pan Adjustment: Rotate the lens base until you are satisfied with the field of view. • Horizontal Rotation: Rotate 3D assembly in the lens base.
Completing the Camera Installation 1. If previously removed, reattach the safety lanyard to the backbox. 2. Reattach the lower dome to the backbox by fastening the three screws. Refer to the following figures for the appropriate method to reattach the lower dome. Figure 13. Incorrect Dome Cover Attachment Method Figure 14. Correct Dome Cover Attachment Method Figure 15. Align Small Hole for Microphone 3. Put on the trim ring and rotate it clockwise to secure the trim ring on the bracket.
Accessing the Camera Anyone who access the camera can view live video. If you want to prevent users from viewing video without logging in, you must change the permissions for public users. The recommended browsers for your camera are the latest version of Internet Explorer®, Microsoft™ Edge™, Google Chrome™ browser, or Mozilla® Firefox®. for supported browser versions, refer to the specification sheet. 1. Open a web browser. 2. Type the camera’s IP address (192.168.0.
REVISION HISTORY Manual # C6644M Date 2/20 Comments Original version. Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies. Product specifications and availability are subject to change without notice. C6644M (2/20) © Copyright 2020, Pelco, Inc. All rights reserved.
Pelco, Inc. 625 W. Alluvial Fresno, California 93711 United States USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.