Installation Manual
Table Of Contents
6
2. Remove either the conduit plug (side) or grommet (top) wire entry.
3. Prepare the wire entry holes:
• If using the grommet: Put the grommet (supplied) aside for use in a later step.
• If using conduit (not supplied): Insert a 25 mm or 3/4 in. conduit adapter (not supplied). For Environmental Vandal cameras,
the conduit adapter and compression glands must be rated for IP66/NEMA 4 applications.
4. Install the surface mounting ring to the mounting plate and use a hand driver to tighten the four tamperproof captive fasteners using
the supplied bit.
5. Pull the wiring through the opening:
• If using conduit (not supplied): Feed the wires through the conduit adapter into the surface mounting ring, and attach the
conduit to the adapter.
• If using the grommet: Feed the wires into the surface mounting ring, pass the unterminated cables through the grommet,
and insert the grommet in the top entry.
Installing the Camera
NOTICE: Take care not to touch the camera lenses during installation.
Dress the wires inside the mount or back box when you finish installing the camera.
Camera Configuration Sequence
When you apply power to the camera, the camera undergoes a configuration sequence, taking approximately two minutes to complete
and come online. If the camera connected to a network without a DHCP server and DHCP is enabled, the configuration sequence can
take up to five minutes to complete.