Sarix® Professional IMP Series Environmental Vandal Dome Quick Start Guide IMP121-1ES IMP321-1ES IMP121-1RS IMP321-1RS IMP221-1ES IMP521-1ES IMP221-1RS IMP521-1RS C2293M-B-EN (12/16)
Contents Contents ....................................................................................................................................................................................... 2 Important Notices Statement ........................................................................................................................................................ 3 Regulatory Notices...........................................................................................................
Important Notices Statement For information about Pelco’s product-specific important notices and thereto related information, refer to www.pelco.com/legal. REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Model Instructions The physical appearance and installation methods for the models indicated within the list below are, by and large, the same. Therefore, please use this quick guide where we take the example from IMP521-1RS as a reference to apply to all the varied models.
Description The Sarix® Professional Series IP Environmental Vandal Dome is ideal for both indoor and outdoor applications.
IN-CEILING FLUSH MOUNT WITH IMPICM-1ER Install the environmental vandal dome camera to an in-ceiling area as shown in the following procedure. 2 3 1 4 1. Utilize torx wrench to loosen the screws on lens base and top cover in order to disassemble the 3 parts of camera individually. 2. Connect the required cables (Ethernet and Alarm/Audio Input/Output threads) with the corresponding ports on rear side. 3.
5 6 Tightening torque: 8 ~ 10kg/cm (17.64 ~ 22.05 lb/in) Tightening torque: 8 ~ 10kg/cm 10 (17.64 ~ 22.05 lb/in) Spring Hook * 2 Protective Cover 5. Use a cross screw driver to turn the 2 bracket screws clockwise to extend the locking arms and tighten them securely to compress the locking arms so that the bracket can be fixed within the in-ceiling area firmly. 6. Based on your needs, use the bottom conduit hole or side conduit hole on lower case for cable entry and connect the cables.
WALL SURFACE MOUNT Install the environmental vandal dome camera to a wall surface as shown in the following procedure. Tightening torque: 8 ~ 10kg/cm (17.64 ~ 22.05 lb/in) Tightening torque: 8 ~ 10kg/cm (17.64 ~ 22.05 lb/in) 1. Based on your needs, use the bottom or side conduit hole on the lower case for cable entry and connect the required cables first. Then mount the lower case on a surface by securing screws (supplied) into the inserted plastic anchors tightly. 2.
PENDANT MOUNT WITH IMPPM-1ER The Pendant Installation involves mounting IMPPM-1ER Sarix Environmental Pendant Mount for Environmental Vandal Dome camera. The camera must be first installed within the pendant mount back box with an adaptor ring before assembled with additional pendant mount brackets. Below are the recommended brackets, which are NOT provided, for additional pendant mount applications for your reference.
2. After wires connection, attach the lens base to the pendant mount back box by aligning the red dots for identification of both parts and securely fasten the 3 screws of the lens base with the torx wrench (supplied). Finally, assemble the top cover with the lens base, both of which, similarly, have red dots for aligning identification, followed by fastening the 3 screws of top cover to complete the installation. Tightening torque: 8 ~ 10kg/cm (17.64 ~ 22.05 lb/in) Tightening torque: 8 ~ 10kg/cm (17.
TOP COVER DEFOG Defog function, which heats up the camera to overcome certain extreme weather conditions (e.g., snow or frost) which may harm the operation of camera, is embedded within this vandal camera.
Pelco Troubleshooting Contact Information If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling. Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only. Note for Dimension Drawings NOTE: VALUES IN PARENTHESES ARE INCHES; ALL OTHERS ARE CENTIMETERS.
Pelco by Schneider Electric 3500 Pelco Way Clovis, California 93612 USA (800) 289-9100 Tel (800) 289-9150 Fax +1 (559) 292-1981 International Tel +1 (559) 348-1120 International Fax www.pelco.com Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc. or its affiliates. ONVIF and the ONVIF logo are trademarks of ONVIF Inc. All other product names and services are the property of their respective companies.