User Manual
59
3.2.6.1 Alarm Source
This page allows user to configure the settings of the connected alarm input source, which is the external alarm signaling
device, such as a door contact or motion detector. Both normally open and normally closed devices are supported.
FIGURE 3-39: ALARM SOURCE
Alarm Input Settings
1. Check Enabled button to enable Alarm Input.
2. Select either Normally Open or Normally Closed from the Polarity drop-down menu.
Normally Open: An alarm will be triggered when the external contact closes.
Normally Closed: An alarm will be triggered when the external contact opens.
Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
3.2.6.2 Motion Detection
This page is designed to define multiple groups of motion detection zones with specific own thresholds for triggering.
FIGURE 3-40: MOTION ZONE AREA SETTING
Motion Zone Area Setting
1. Check Enabled button to enable Motion for any or all of Zones 1 to 4.
NOTE: Click on the button “ ” to expand section of each zone setting, and click the button “ ” to collapse each section.
2. Sensitivity: Choose different levels of sensitivity from High, Medium, and Low.
High: Motion is activated with slight changes in brightness or motion.
Low: Motion is activated with big changes in brightness or motion.
Medium: The threshold of sensitivity is in the middle between High and Low.
3. Object Size can be defined from the range 1 to 100 for detection on wanted objects.
4. Set the desired area to trigger motion detection. The red frame of motion setup will appear for defining the
detection area by dragging the mouse.