I N S T A L L A T I O N Sarix Enhanced Series III ® Box (IXE) Camera Models C6659M (3/20)
C6659M (3/20)
Contents Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Regulatory Notices (FCC Class A). . . . . . . . . . .
C6659M (3/20)
Important Notices REGULATORY NOTICES (FCC CLASS A) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules.
POWER SOURCE This product is intended to be supplied by a Listed Power Adapter or DC power source marked Class 2 or L.P.S. (or “Limited Power Source”), rated 12Vdc, 2A, or 24Vac (50/60 Hz), 1.5A. When used with Power over Ethernet (PoE), the Power Sourcing Equipment (PSE) shall comply with IEEE802.3af and Limited Power Source (LPS) according to clause 2.5 of IEC/EN/UL 60950-1 or annex Q of IEC/EN/UL62368-1. KOREAN CLASS A EMC ESD WARNING WARNING: This product is sensitive to Electrostatic Discharge (ESD).
C6647M (3/20) 7
Description The Sarix Enhanced III Series Box cameras are compatible with a choice of standard iCS (Intelligent CSmount) megapixel lenses for wide angle or long range surveillance needs. The Sarix Enhanced III Series Box camera offers flexible mounting options, and uses a standard Web browser for easy remote setup and administration. The Sarix Enhanced III Series Box camera easily connects to Pelco IP and hybrid systems such as VideoXpert, VX Toolbox, Endura version 2.
BOX CAMERA MODELS SUPPLIED PARTS LIST Qty 1 1 1 1 Description Camera Installation manual Important Safety Instructions document China RoHS document USER-SUPPLIED PARTS LIST In addition to the standard tools and cables required for a video security installation, you will need to provide Qty Description 1 iCS megapixel lens 1 Up to 256 GB Micro SDHC or SDXC card capable of a minimum write speed of 10 MB/sec is recommended for recording HD video (optional) 1 RJ-45 connector to terminate cable 1 Cat5e (or hig
Product Overview Figure 1. Sarix Enhanced III IXE Series Box 1. Status LED Indicators: a. Solid red for more than 5 seconds indicates there is a booting error. Flashing green indicates booting is normal. b. Flashing orange indicates a firmware update is in progress. c. LED will turn off after a successful boot up. d. Solid amber indicates the camera is in a cold start state (warming up before fully booting). 2. Alarm/Relay/Audio Port: Connects to alarms, relays, and audio in/out. 3.
Installation NOTE: Pelco megapixel (MP) iCS lenses have been designed and tested to deliver optimal image quality for the IXE Series box camera. This camera only accepts iCS lenses. Using a non-iCS lens may damage the camera. Please contact Pelco for more information. 1. Install the iCS lens. a. Remove the outer cover from the lens mount. Figure 2. Remove the Cover from the Lens Mount b. Tighten the iCS lens onto the lens mount.
Figure 4. Connect the iCS Lens Cable to the Connector d. (Optional) Insert a Micro SD Card into the slot. NOTE: Do not remove the microSD card when the camera is powered on. Figure 5. Insert a Micro SD Card 2. Install the camera on the mount in the desired location (refer to the installation/operations manual for the recommended mount).
ETHERNET WIRING REQUIREMENT FOR POE Connect a Cat5e cable or higher cable (not supplied) to the RJ-45 network connector. The 8-pin port includes video over Ethernet, and PoE for the camera. PoE injects power over the same cabling that carries the network data, eliminating the need for a separate power supply. This simplifies the installation and operation of the camera without affecting network performance. Figure 6. Pin Numbering Figure 7.
ALARM/RELAY/AUDIO PORT Designation Function AI Alarm In + GND Ground Alarm Input Alarm Output GND Ground AO Alarm Out + COM Common Audio In + Audio In Audio In Audio Out + Audio Out Audio Out - Figure 8. Relay and Alarm Connections Figure 9. Box Pinout Detail ACCESSING THE CAMERA Anyone who access the camera can view live video. If you want to prevent users from viewing video without logging in, you must change the permissions for public users.
• In its out-of-the-box configuration, the camera has no user name and password assigned. For security purposes, it is recommended that you set an administrative user name and password after initial configuration of the camera. Creation of an administrative user name changes the state of the camera to its “operational mode,” where credentials must be provided in order to change its configuration. • There is no provision for recovering a forgotten administrator user name or password.
Pelco, Inc. 625 W. Alluvial Fresno, California 93711 United States USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.