I N S TA L L AT I O N / O P E R AT I O N ® MPTAZ Series Pan/Tilt and Scanner Control C528M-E (4/03)
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................................................................................................. 3 DESCRIPTION ..................................................................................................................................................................................................................... 4 MODELS ......................................................
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit meets NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P standards, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
DESCRIPTION The controls in the MPTAZ Series operate 120 VAC, 230 VAC, and 24 VAC pan/tilts or scanners. All models include auto/ random/manual scan operation, pan/tilt operation with a joystick, and lens control.
INSTALLATION The MPTAZ Series Control is shipped from the factory for pan/tilt operation. If you are connecting the control to a pan/tilt, skip step 1 and proceed to step 2, Electrical Connections. 1. To operate a scanner with the MPTAZ Series, reset the control’s jumper JP5 to the SCANNER position. Jumper JP5 is factory set in the P/T position. Refer to Figure 1 for the internal configuration of the PC board. Figure 1.
2. Electrical Connections - Follow the correct instructions for your control model. Cable Distances: Pan/Tilt or Scanner Refer to the installation manual for the specific scanner or pan/tilt to be used with the control. Lens The following lens distances are the approximate maximum recommended under the following conditions: • Based on a 35 mA load @ 12 VDC • Single lens function activation • 10% line loss in voltage at the lens motor (0.3 mm2) (0.5 mm2) (1.
MPTAZ115DT or MAPTAZ220DT - Assemble the mating connector. Refer to Figure 4 and perform the following steps. a. Slide the connector clamp assembly over the conductor cable. If the diameter of the conductor cable is such that the rubber boot will slide over it easily, slide the rubber boot onto the conductor cable at this time. If not, discard the rubber boot. b. Refer to Detail A in Figure 4. Prepare the wires from the conductor cable as follows: • Strip at least one inch (2.
OPERATION To operate the MPTAZ Series Control, use the push buttons to control the lens, and move the joystick to control the pan/tilt or scanner. The MPTAZ Series Control has two modes of automatic pan/tilt operation: random scan and auto scan. Random activation causes scanning between the limit stops in an unpredictable pattern. To activate random mode, press the SELECT switch until the LED next to RANDOM is lit. Auto scan will operate the pan/tilt between limits for 30 minutes.
MAINTENANCE Under normal operating conditions and usage, maintenance of this equipment is not necessary. However, if maintenance is required, contact a qualified service technician or return to the factory for repair.
SPECIFICATIONS ELECTRICAL Input Voltage MPTAZ115DT, MPTAZ24DT: MPTAZ24DT/220, MPTAZ220DT: Output Voltage MPTAZ24DT, MPTAZ24DT/220: MPTAZ115DT: MPTAZ220DT: Lens Voltage: Fuse Protection MPTAZ115DT, MPTAZ24DT: MPTAZ24DT/220, MPTAZ220DT: Power Cord: Connectors MPTAZ115DT, MPTAZ220DT: MPTAZ24DT, MPTAZ24DT/220: Conductor Requirements: 120 VAC, 50/60 Hz 230 VAC, 50/60 Hz 24 VAC 120 VAC 230 VAC 0-12 VDC 1 ASB 0.
REGULATORY NOTICES This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.