CONTENTS Section Page IMPORTANT SAFETY INSTRUCTIONS ............................................................................................................................................................................... 5 DESCRIPTION ..................................................................................................................................................................................................................... 6 MODELS ...............................................
GAIN/AGC ................................................................................................................................................................................................................ 34 IR FILTER MODE (MODELS ES30PCBW18/ES31PCBW18 ONLY) ............................................................................................................................. 35 LIMIT STOPS ...................................................................................................
C311M-L (1/05)
IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8.
DESCRIPTION The ES30PC/ES31PC Esprit Series is designed to protect camera optics and electronics from moisture and airborne contaminants. The system features a receiver, pan and tilt, enclosure, and a pressurized integrated optics cartridge (IOC). The integrated optics cartridge packages an auto focus camera, lens, heater, and sensors in a small, self-contained unit pressurized to 10 psig with dry nitrogen.
INSTALLATION When installing the ES30PC/ES31PC Esprit® system, allow for sufficient clearance between the top of the unit and overhead obstructions. This will prevent interference when the enclosure is driven to its maximum elevation of 33 degrees.
120/230 VOLTAGE SELECTOR SWITCH Route the wires and cables through the center of the Esprit mount. Reinstall the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation. ES30PC-5/ES31PC-5 Models Only – Set the 120/230 voltage selector switch on the transformer to the appropriate voltage. Connect wires and cables. a. Connect to power. Use the two supplied clamp connectors to connect the AC line and neutral.
Turn on the power. If the red LED lights, turn off the power and proceed to the next step. If the red LED does not light, refer to the Troubleshooting section. Plug the male Esprit system connector, located on the bottom of the pan and tilt, into the female Esprit system connector located on the transformer module. Align the pan and tilt part number with the alignment label of the base and then attach the pan and tilt to the base with three 1/4-20 nuts and washers (supplied).
TXB SERIES TRANSLATOR BOARD INSTALLATION (OPTIONAL) Pelco’s TXB Series allows controllers from other companies to communicate with the Esprit system. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover is removed, refer to the manual supplied with the translator board to complete the installation. HOW TO REMOVE THE PAN AND TILT COVER 1. 2. 10 Unscrew the Phillips head screw located on the left cover of the pan and tilt. Remove cover and place to the side.
HOW TO REINSTALL THE PAN AND TILT COVER The pan and tilt covers must be properly seated and have a tight seal all the way around when installed. To reinstall the pan and tilt cover, do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit under the front and back rain guards of the pan and tilt, and the top of the cover must seat against the lip of the top gasket. 2. Apply pressure and push the top of the cover down to align the fastener holes. 3.
OPERATION POWER-UP DISPLAY When the system is powered up, the selected protocol, revision number, and other information is displayed on the monitor. For example, the screen might show the following information: ESPRIT 16X IOC 2.00 CONFIGURE DONE D Address 1 P Address 2 Comm 2400, N, 8, 1 The information displayed depends on the selected protocol (C, D, or P) and the menu selection for powerup mode. (Refer to the Power-Up Mode in the Programming section).
PRESSURIZED INTEGRATED OPTICS CARTRIDGE The pressurized IOC houses an auto focus camera, lens, heater, and sensors in a self-contained, sealed unit. Dry nitrogen pressurized to 10 psig controls the environment inside the cartridge, eliminating internal condensation and corrosion. Sensors strategically placed inside the pressurized IOC continually monitor pressure, temperature, and relative humidity.
CURRENT READING MENU IOC Internal Reading Temperature Dewpoint Pressure 37 C 98 F 08 C 46 F 10.30 psig 0.71 bar Refresh Exit The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An asterisk displayed to the left of a menu item denotes that an alert condition exists. Due to the heat emitted from the electronics of the camera, normal temperature operating range is approximately 95°F.
ZONES A zone is a programmed pan area with set boundaries and identifying label. The Esprit system has a maximum of eight zones, each with a 20-character label. Zones can be programmed to blank video when the camera pans into the zone area. If a zone is blanked, the system displays the message, VIDEO BLANK. (Refer to Zone Blank in the Programming section for instructions.) PATTERNS The Esprit system can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.
PROGRAMMING – ES30PC16/ES31PC16 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections. Iris Open: Enter. Camera Menu Iris Close: Cancel.
PROGRAMMING – ES30PC22/ES31PC22 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections. Iris Open: Enter. Camera Menu Iris Close: Cancel.
PROGRAMMING – ES30PCBW18/ES31PCBW18 1. Access main menu (preset 95). 2. Make main menu selections. Joystick: Move up or down to position cursor or to toggle between selections. Iris Open: Enter. Camera Menu Iris Close: Cancel.
PROGRAMMING ACCESSING MAIN MENU (PRESET 95) You can call up the main menu on your monitor by programming (setting or creating) preset 95 (28 if in 32-preset mode). Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for programming preset 95 are given below for various Pelco controllers. CM6700 1. Enter the number of the camera and press the CAM key. 2. Enter 95 and hold the PRESET key for two seconds. 3.
ACK ACT (ACKNOWLEDGE ACTION) MAIN MENU ACK Alert Exit Alert Menu Repeat Constant Disp Pos Top Right ACK Act Always On Alert Reset Exit If an enivornmental condition inside of the IOC goes outside of the factory set limits (such as “Low Pressure”) then select ACK Alert to activate the alert label behavior. Program ACK Act to establish alert label behavior after alert acknowledgement.
ALERT DISPLAY POSITION MAIN MENU Alert Menu ACK Alert Exit Repeat Constant Disp Pos Top Right ACK Act Always On Alert Reset Exit Screen positioning of the alert label is user-defined. Positioning options include the following: Top Left Top Right Center Bottom Left Bottom Right To set the alert label position: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Alert. 3.
ALERT REPEAT MAIN MENU Alert Menu ACK Alert Exit Repeat Constant Disp Pos Top Right ACK Act Always On Alert Reset Exit You can program how often an ALERT label is repeatedly displayed until it is acknowledged by the system controller. The following settings are available: Constant 15 min off 30 min off 60 min off The ALERT label is continually displayed on the monitor until acknowledged.
AUTO FOCUS MODE MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto There are two auto focus modes: Auto – If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place the focus in the manual mode.
AUTO IRIS MAIN MENU ACK Alert Exit Auto Iris Menu Camera Menu Backlight comp Zoom limit Reset camera Next Exit Off x- - Auto-iris mode Auto-iris level Auto-iris peak Exit Auto The following are the settings for auto iris: Mode Level Peak To change the settings for auto iris: 1. 2. 3. 4. 5. 6. Program preset 95 (28). The main menu appears. Position the cursor (>) beside Camera.
AUTO IR LEVEL (MODELS ES30PCBW18/ES31PCBW18 ONLY) MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit IR Filter Menu Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto Auto IR filter mode Auto IR Level Exit Auto Dusk The auto IR level is the light level at which the infrared filter switches IN or OUT.
AUTO SHARPNESS MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Sharpness Menu Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto Auto Auto Sharpness Sharpness Exit On 13 The following settings are available for auto sharpness: On – Automatically sets the sharpness of the camera.
AZ/EL MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Az/El programs the horizontal display position of the Azimuth1/Elevation2 label.
AZ/EL LINE MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Az/El Line controls the vertical display position of the Azimuth/Elevation label. The label may be displayed on lines 3 through 10.
AZIMUTH ZERO MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Azimuth is the pan angle from 0 to 359 degrees. Azimuth zero is the programmed zero-degree point that is normally set to magnetic north.
BACKLIGHT COMPENSATION MAIN MENU Camera Menu ACK Alert Exit Backlight comp Zoom limit Reset camera Next Exit Off x- - There are two backlight compensation modes: On – The system uses the center 10 percent of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white.
DIRECTION MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Direction programs the horizontal display position of the Direction label (N, NW, NE, …).
DIRECTION LINE MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Direction Line controls the vertical display position of the Direction label. The label may be displayed on lines 3 through 10.
DISPLAY DURATION MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Display Duration programs the duration the Az/El, Direction, and Zoom labels are displayed on the monitor.
GAIN/AGC MAIN MENU ACK Alert Exit Gain/AGC Menu Camera Menu Backlight comp Zoom limit Reset camera Next Exit Off x- - Gain Limit Exit 27 GAIN LIMIT The gain limit sets the maximum level for the automatic gain control. Increasing the level will increase the signal level and increase the noise level of the picture. To change the gain: 34 1. Program preset 95 (28). The main menu appears. 2.
IR FILTER MODE (MODELS ES30PCBW18/ES31PCBW18 ONLY) MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit IR Filter Menu Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto Auto IR filter mode Auto IR Level Exit Auto Dusk There are two settings for the IR filter mode: IMPORTANT: Automatic shutter speed must
LIMIT STOPS Limit Stop Menu MAIN MENU ACK Alert Exit Limit Stops Set Man Limits Clear Man Limits Set Scan Limits Clear Scan Limits Exit Off NOTE: Limit stops are inactive while setting items in the program menu (e.g. azimuth zero, scan limits, manual pan limits). TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3.
LIMIT STOPS MENU The manual pan limit stops can be set at the controller using the Limit Stops menu: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limit Stop. 3. Press the Iris Open button to enter the Limit Stop menu. 4. Move the cursor to Set Man Limits and press the Iris Open button. PRESS IRIS OPEN TO SET LEFT LIMIT appears. 5. Move the pan and tilt to the desired left limit position and press the Iris Open button to set the left manual limit.
Scan Limit Stops When scan limit stops are set, the pan and tilt reverses direction during random, frame, or auto scanning when a limit stop is reached. The manual scan limit stops can be set in one of two ways: At the controller by programming presets 92 and 93 or At the controller by programming the Limit Stops menu PRESETS Refer to the documentation for your control system for programming presets, and then do the following: 1. 2. 3. 4. 5. Make sure limit stops are turned ON, then exit the menu.
LINE SYNCHRONIZATION MAIN MENU ACK Alert Exit Line Sync Menu Line Sync Line Sync Phase Exit On 0 If cameras are out of phase with each other, they may produce what appears to be vertical roll when switching between cameras. There are two settings for line synchronization: On – Adjust the synchronization of the power line voltage so that it is in phase with other cameras. Off – The system synchronizes to an internal clock.
LOWLIGHT LIMIT (MODELS ES30PC22/ES31PC22 AND ES30PCBW18/ES31PCBW18 ONLY) MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto This setting determines the maximum length of time the shutter will remain open automatically in low light conditions.
PARK TIME MINUTES MAIN MENU ACK Alert Exit Other Menu Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 90 MPH wind Exit This feature causes the system to park at preset 1 after a programmed number of minutes of control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature.
PATTERN LENGTH MAIN MENU ACK Alert Exit Other Menu Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 90 MPH wind Exit The Esprit can do the following: One full pattern - 1.5, 3, or 6 minutes long or Two half patterns - .75, 1.5, or 3 minutes long This pattern can consist of any standard pan and tilt or lens command. Presets, flip, and turbo are not allowed in a pattern.
POWER-UP MODE MAIN MENU ACK Alert Exit Power-Up Menu Power Up Exit Default This feature lets the dome resume a desired condition following power-up. The menu includes the following choices. • Default – On power-up, the system goes through a configuration cycle and stops at zero reference, showing “Configuration Done,” address, and mode settings on the screen. • Park – The system moves to preset 1 when the power-up sequence finishes.
PROPORTIONAL PAN MAIN MENU ACK Alert Exit Other Menu Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit There are two proportional pan modes: On – Enables the proportional pan mode. The amount of zoom controls the pan and tilt. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide zoom settings.
RESET CAMERA MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Off x- - Resetting the camera returns the settings to their defaults.
SCAN SPEED MAIN MENU ACK Alert Exit Other Menu Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan modes: auto, random, and frame scan. To change the scan speed: 46 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other. 3.
SHARPNESS MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Sharpness Menu Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto Auto Auto Sharpness Sharpness Exit On 13 Use the Sharpness setting to manually set the sharpness of the camera. To manually set the sharpness of the camera: 1. Program preset 95 (28).
SHUTTER SPEED MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto There are several electronic shutter speed settings: Auto 1/2 1/4 1/8 1/15 1/30 1/60 1/120 1/180 1/250 1/500 1/1000 1/2000 1/4000 1/10,000 1/30,000 In the Auto setting the camera controls the shutter spe
SPEED PROFILE MAIN MENU ACK Alert Exit Other Menu Proportional pan On Park time minutes 0 Scan Speed deg/s 25 Pattern Length 1.5 min Spd Profile 50 MPH wind Exit This feature allows the operator to set the wind speed conditions for the location of the Esprit system. You can set two wind speed profiles of 50 mph or 90 mph in which the system will remain operational.
WHITE BALANCE MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit White Balance Menu Next Menu Off x- - LowLight limit Shutter speed Auto focus mode Prev Exit Auto Auto Auto Auto white bal Red bal level Blue bal level Exit On 182 182 The settings for white balance are as follows: Auto white bal R Gain B Gain To change the white balance
WIPER MODE Wiper Menu MAIN MENU Wiper Mode Momentary Wiper Dwell 2 Wiper Time 60 Exit ACK Alert Exit There are three wiper settings: Wiper Mode Wiper Dwell Wiper Time To change the wiper settings: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Wiper. 3. Press the Iris Open button to enter the Wiper menu. 4.
ZONES Basic rules for setting zones: 1. 2. 3. 4. Refer to the documentation for your control system to program zones. Establish zones using the controller, prior to programming ZONE BLANK with the Esprit onscreen menu. To accurately set zone areas, zoom wide to the maximum field of view. Set zones moving the joystick left to right. The left position is always the start position.
ZOOM MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Zoom programs the horizontal display position of the Zoom label. The following settings are available for the Zoom label: Off – Label is not displayed.
ZOOM LIMIT MAIN MENU ACK Alert Exit Camera Menu Backlight comp Zoom limit Reset camera Next Exit Off x- - ES30PC16/ES31PC16 – 16X optical zoom and 10X electronic zoom ES30PC22/ES31PC22 – 22X optical zoom and 10X electronic zoom ES30CPBW18/ES31PCBW18 – 23X optical zoom and 10X electronic zoom To change the zoom limit: 54 1. Program preset 95 (28). The main menu appears. 2.
ZOOM LINE MAIN MENU ACK Alert Exit Az/El/Direction Other Menu Proportional pan Park time minutes Scan Speed deg/s Pattern Length Spd Profile Exit On 0 25 1.5 min Set Azimuth Zero Az/El Az/El Line Direction Direction Line Zoom Zoom Line Disp Duration Exit Zoom Line controls the vertical display position of the Zoom label. The label may be displayed on lines 3 through 10.
TROUBLESHOOTING NOTE: The system contains no user-serviceable parts. If there is a problem with your system, it must be returned to Pelco for servicing. Symptom: System does not operate. 1. Check system input voltage. 2. The Esprit system is protected by a resettable overcurrent protective device located in the transformer module. Whenever a fault condition is experienced in the system causing excessive current flow through the protective device, a change occurs that will prevent current flow.
Symptom: No video or poor video 1. Check the video and power connections to the camera. 2. Check for power to the camera from the Esprit system camera power output. 3. Check all coax BNC connectors from the camera to the monitor. 4. Make sure the controller is set for the correct camera-to-monitor viewing combination; for example, Camera 1 to Monitor 1. Refer to the controller manual for information. 5. Check for normal load termination of 75 ohms.
MAINTENANCE Clean the enclosure window periodically with a mild non-abrasive detergent in water and a soft cloth to help maintain picture clarity. If operating problems are experienced with the system, refer to the Troubleshooting section. WIPER If the window wiper assembly is installed, replace worn or deteriorated wiper blades immediately. At a minimum, replace wiper blade once a year.
PRESSURIZED IOC IMPORTANT: Disconnect power to the Esprit system before removing or installing the pressurized cartridge. Software conflicts can occur if the Esprit is not powered-down before removing/installing the IOC. There are no user-serviceable parts internal to the pressurized integrated optics cartridge. If vessel fails, Pelco recommends that it be returned to the factory for replacement or repair. Removing the IOC 1. Remove the 4 Phillips screws located on the outside viewing window.
APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switch settings have no effect on Coaxitron control signals. Table A. Switch Settings for SW1 Switch Setting Baud Rate SW1-1 SW1-2 SW1-3 2400 OFF OFF OFF* 4800 ON OFF OFF* 9600 OFF ON OFF* * SW1-3 is not used; set it in the OFF position.
Table B. Switch Settings for SW2 NOTE: The Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switches settings have no effect on Coaxitron control signals.
Table B.
Table B.
SPECIFICATIONS ELECTRICAL Input Voltage: Power Requirements: Heater and Defroster: Defogger: Electrical Connections: Aux 2: MECHANICAL Construction System: EWM Wall Mount: EPA Pedestal Adapter: Finish System: EWM Wall Mount: EPA Pedestal Adapter: Viewing Window: Window Viewing Area: CAMERAS Scanning System ES30PC16/ES31PC16 and ES30PC22/ES31PC22: ES30PCBW18/ES31PCBW18: Image Sensor: Effective Pixels ES30PC16/ES31PC16 NTSC: ES30PC16/ES31PC16 PAL: ES30PC22/ES31PC22 NTSC: ES30PC22/ES31PC22 PAL: ES30PCBW18/ES
Sensitivity ES30PC16/ES31PC16: ES30PC22/ES31PC22: ES30PCBW18/ES31PCBW18: Synchronization System: White Balance: Shutter Speed: Iris Control: Gain Control ES30PC16/ES31PC16: ES30PC22/ES31PC22: ES30PCBW18/ES31PCBW18: Video Output: Signal to Noise Ratio ES30PC16/ES31PC16: ES30PC22/ES31PC22: ES30PCBW18/ES31PCBW18: Construction: Finish: Viewing Window: Operating Temperature: Operating Environment: Dimensions: Unit Weight Standard with IOC: With Wiper and IOC: Ratings: 0.
C311M-K (9/04)
REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.