® HS8000/HS8013 High-Security Camera Enclosures Installation/Operation Manual C480M-F (10/04) Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.
CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 1 2.0 DESCRIPTION .......................................................................................... 2 2.1 OPTIONS ........................................................................................... 2 3.0 INSTALLATION .......................................................................
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
2.0 DESCRIPTION The HS8000/HS8013 is a high security camera enclosure designed for installations such as prisons, detention cells, etc., requiring maximum protection from vandalism. Constructed from heavy gauge steel, the HS8000 will accept most CCD cameras with fixed focal length lenses ranging in size from 4 mm to 75 mm. Larger lens size combinations can be considered when using the HS8013. There is no exposed mounting hardware securing the HS8000/HS8013 to its mounting surface.
3.0 INSTALLATION NOTE: Unless otherwise noted all instructions, drawing, etc. apply to both the HS8000 and HS8013 except for the ceiling adapter. The HS8000CA ceiling adapter will not work with the HS8013. Before installing the enclosure to a wall or ceiling, make certain that the mounting surface is able to support the full load of the enclosure plus all other equipment such as camera, lens, etc. The tilt table bracket may be removed to provide adequate clearance for mounting the enclosure.
1" Cable Entry Hole, 2X HS8000/HS8013 Mounting Template 3.25" .75" 2.0" Figure 1.
3.2 WALL/CEILING MOUNTING To mount the enclosure to a wall or ceiling, follow the steps outlined below. 1. Remove the two (2) tamper-resistant screws and open the cover. A special socket is provided (fits 1/4" square drive). 2. Using the enclosure or the template provided (see Figure 3), mark and drill holes in the mounting surface. 3. Knock out any of the two (2) cable entry holes desired on the enclosure body. 4. Attach the enclosure with the required fasteners. 5.
3.4 HS8000CA CEILING ADAPTER PLATE INSTALLATION (For HS8000 only) Before installing the HS8000CA ceiling adapter plate, make sure the mounting surface is able to support the full load of the enclosure, mount, and all other equipment such as the camera, lens, etc. NOTE: The HS8000CA ceiling adapter plate is provided with six (6) 10-32 screws, nuts and nylon washers. Before continuing with the installation of the adapter plate, make sure these six screws, nuts and washers are included.
3.5 OPTIONAL HK8000/HK8024 HEATER KITS The HK8000 and HK8024 Heater Kits require 120 VAC or 24 VAC respectively, and both provide 80 watts of heat which is thermostatically controlled to activate at 40° F and turn off at 60° F 3.5.1 Recommended Cable Size The following cable sizes are the minimum recommended for use with heater kits. 120 VAC Operation 24 VAC Operation 22 Awg to 400 ft (121.9 m) 20 Awg to 650 ft (198.12 m) 18 Awg to 1,100 ft (335.3 m) 20 Awg to 35 ft (10.7 m) 18 Awg to 60 ft (18.
3.7 CAMERA/LENS INSTALLATION NOTE: The tilt table bracket and tilt table may be removed from the enclosure to aid in camera/lens installation. Now that the proper window viewing location has been determined and the enclosure has been mounted, you are ready to mount your camera lens to the enclosure. Refer to the following steps. 1. Loosen the tilt table mounting bolts. 2. Securely attach the camera/lens to the desired location on the tilt table. 3.
4.0 CARE AND MAINTENANCE Regularly scheduled maintenance will help prolong the operational life and appearance of the equipment. Clean the viewing window regularly with a soft cloth, using a mild, nonabrasive detergent and water solution to help maintain picture clarity.
5.0 EXPLODED ASSEMBLY DRAWING Figure 6. HS8000 Exploded Assembly Drawing Table A. Mechanical Parts List Item Quantity 1 2 1 1 1 1 1 1 1 1 1 2 1 1 5 1 1 1 1 3 4 5 6 7 8 9 10 11 12 13 14 15 10 Description Part Number Window, Lexan, 5.75" x 4" x .
6.0 SPECIFICATIONS MECHANICAL Window: 1/2" (1.27 cm) thick; impact and abrasion resistant Lexan Camera Mounting: Adjustable tilt table Camera and Lens Size: Accepts camera and lens combinations (including BNC connector) up to: HS8000 4.0" H x 4.0" W x 8.0" L (10.16 cm x 10.16 cm x 20.32 cm) HS8013 4.0" H x 4.0" W x 11.0" L (10.16 cm x 10.16 cm x 27.94 cm) Enclosure Mounting: Four (4) .390" (0.99 cm) diameter holes on protected rear surface Security: Tamper-resistant screws N.O./N.C.
Figure 7. HS8000/HS8013 Dimension Drawing Figure 8.
NOTES Pelco Manual C480M-F (10/04) 13
7.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products and the following fixed camera models: CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and CC3651H-2X.