I N S T A L L A T I O N Spectra® IV Series Spectra® IV SE Series Pendant Mount Back Box C3418M (8/06)
Installation 1 3 2 2 C3418M (8/06)
1. Install the mount for the pendant dome. Refer to the instructions supplied with the mount. 2. Open the hinged door to the back box. Push the tab lock towards the wall of the unit and lift the door open. Pull wiring into the back box. Refer to Table A, Table B, and Table C for wiring distances. 3. Screw the back box onto the mount. If outdoors, apply thread compound (provided) to the threads on the back box. NOTE: Thread compound must be applied.
ALARMS AUX1 1 2 3 4 5 6 7 GND NO COM NC AUX2 GND VIDEO PWR- GND PWR+ RX- RX- TX- TX- UTP+ UTP- 5 4 C3418M (8/06)
WARNING: An electrical short in the back box may occur if the metal BNC connector is not completely covered by the protective boot. 4. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the power. The green LED will light.
SWITCH 1 AND 2 6 8 7 6 C3418M (8/06)
6. Configure DIP switches SW1 and SW2 located on the top of the dome drive. For DIP switch settings, refer to the labels located on the top of the dome drive or to the Switch Settings section. NOTE: When connecting more than one Spectra dome to a single controller, terminate the unit farthest from the controller. To terminate the dome drive set the SW2-10 switch to the ON position. 7. Install the dome drive. Line up the blue and red tabs with the blue and red arrows on the hinged door inside the back box.
Troubleshooting If your dome does not power up properly after installation, use the following steps. 1. Check the fuse on the circuit board inside the back box for continuity. Replace the fuse if needed. 2. Check the wiring with a volt meter to ensure proper voltage is being received into the back box. If your dome powers up correctly, but you do not have accurate control, use the following steps. 1. Check the signal with a volt meter or an oscilloscope.
Switch Settings WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly. The switches are set at the factory at the defaults for D-type control (2400 baud and address 1). Table D. Switch Settings for SW2 Special Systems Switch Number AD-32 Preset System 1 2 3 4 5 6 7 8 9 10 ON CM9502 Setting ON Vicon Not currently available; SW2-3 is reserved for future use.
Table E. Switch Settings for SW1, P-Type Control NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF. For D-type control systems, refer to Table F.
SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 31 ON ON ON ON ON OFF OFF OFF 71 ON ON ON OFF OFF OFF ON OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 72 OFF OFF OFF ON OFF OFF ON OFF 33 ON OFF OFF OFF OFF ON OFF OFF 73 ON OFF OFF ON OFF OFF ON OFF 34 OFF ON OFF OFF OFF ON OFF OFF 74 OFF ON OFF ON OFF OFF ON OFF 35 ON ON OFF OFF
SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 12 SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 111 ON ON ON ON OFF ON ON OFF 151 ON ON ON OFF ON OFF OFF 112 OFF OFF OFF OFF ON ON ON OFF 152 OFF OFF OFF ON ON OFF OFF ON ON 113 ON OFF OFF OFF ON ON ON OFF 153 ON OFF OFF ON ON OFF OFF ON 114 OFF ON OFF OFF ON ON ON OFF 154 OFF ON OFF ON ON OFF OFF ON 115 ON ON OFF OFF
SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 SWITCH SETTING SPECTRA ADDRESS SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 191 ON ON ON ON ON ON OFF ON 223 ON ON ON ON ON OFF ON 192 OFF OFF OFF OFF OFF OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON ON 193 ON OFF OFF OFF OFF OFF ON ON 225 ON OFF OFF OFF OFF ON ON ON 194 OFF ON OFF OFF OFF OFF ON ON 226 OFF ON OFF OFF OFF ON ON ON 195 ON ON OFF OFF OFF
Specifications GENERAL Construction Back Box Dome Drive Lower Dome Cable Entry (Back Box) Pan Movement Vertical Tilt Manual Pan/Tilt Speeds* Pan Tilt Preset Speeds Pan Tilt Environment Operating Temperature Standard Pendant Maximum Minimum Environmental Pendant Maximum Minimum Aluminum Aluminum, thermoplastic Acrylic Through 1.5-inch NPT pendant mount 360° continuous pan rotation Unobstructed +2° to -92° 0.1°- 80°/sec manual operation, 150°/sec turbo 0.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. If a warranty repair is required, the Dealer must contact Pelco at (800)þ289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial number 2. Date of shipment, P.O.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.