I N S T A L L A T I O N Spectra® Mini IP Dome System C3446M (7/08)
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 System Models. . . . . . .
List of Illustrations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DHCP Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Endura Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Private Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 7. Only use attachments/accessories specified by the manufacturer. 8. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus. 9.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
Description The Spectra® Mini IP dome system is an indoor mini dome system with a built-in 100Base-TX network interface for live streaming to a standard Web browser (Microsoft® Internet Explorer® or Firefox®). The Spectra Mini IP dome features open architecture connectivity for third-party software recording solutions and is also Endura Enabled™ to record, manage, configure, and view multiple live streams.
PARTS LIST The following parts are supplied with the Spectra Mini IP dome system: Qty Description 1 Dome drive 1 Dome bubble with trim ring 1 Installation manual (C3446M) 1 Operation/Configuration manual (C3447M) 1 Spring paddle flex assembly 1 Hardware kit 2 #10 x 1.50-inch self-tapping screws for suspended ceiling installation 2 #8-32 x 3.50-inch machine screws for suspended ceiling installations 2 #8 x 3.
BASIC SYSTEM CONFIGURATIONS The following illustrations demonstrate the possible configurations of Spectra Mini IP with a variety of network options. IMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated.
DHCP NETWORK In this configuration, the DHCP network is accessed through the Web browser. NOTE: For a secure network, Pelco recommends placing the dome behind a firewall. Refer to Table A on page 8. Figure 1. DHCP Network Example ENDURA NETWORK Refer to Table A on page 8. Figure 2.
PRIVATE NETWORK When using a private network, the PC used to operate the Web browser acts as the server. If a static IP network is being used rather than a DHCP network, the dome system is assigned a default IP address of 192.168.0.20 on netmask 255.255.0.0. After the first dome system is plugged in and recognized on a static IP network, you must manually change the IP address of the dome system before plugging in any additional dome systems.
STATIC NETWORK When using a static network, the PC used to operate the Web browser must use the same subnet mask as the dome systems to which it is connected. When the first dome system is plugged into the network, it is assigned a default IP address of 192.168.0.20 on netmask 255.255.0.0. After the first dome system is plugged in and recognized on a static IP network, you must manually change the IP address of the dome system before plugging in any additional dome systems.
Cover and Back Box Installation The Spectra Mini IP is an indoor dome system designed for ceiling applications. The dome can be mounted to the surface of ceilings, or it can be recessed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) tiles in suspended ceilings. SURFACE MOUNT INSTALLATION 1. Prepare the ceiling as follows: a. Using the surface mount ring as a template, drill holes for the mounting hardware. • • b.
Figure 5. Ceiling Installation Figure 6. Concrete Ceiling Installation 6-32 Toggle Bolts (not supplied) #8 x 3.50-Inch Self-Tapping Screws (supplied) NOTE: Use either toggle bolts or self-tapping screws when mounting the dome to a standard ceiling.
RECESSED INSTALLATION SUSPENDED CEILING 1. Remove the spring paddle flex assembly from the surface mount ring (refer to Figure 7). Figure 7. Spring Paddle Flex Assembly 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the dome drive. 3.
9. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and dome bubble into place. 1LINE OUT + 2LINE OUT 3LINE IN + 4LINE IN 5AUX + 6AUX 7ALARM8ALARM+ Figure 8. Removing the Surface Mount Ring Figure 9. Recessed Installation Spring Paddle Flex Assembly #8-32 x 3.
HARD CEILING 1. Remove the spring paddle flex assembly from the surface mount ring. 2. Remove the surface mount ring from the dome drive as follows (refer to Figure 8 on page 15): a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the dome drive. 3. Attach the spring paddle flex assembly to the dome drive using the two #8-32 x 3.50-inch machine screws (supplied).
Wiring Tables CAT5 CABLE Connect a Cat5 cable to the RJ-45 network connector. The 8-pin RJ-45 connector includes video and PoE for the dome system. PoE (IEEE 802.3af) injects power over the same cabling that carries the network data, eliminating the need for a separate power supply; this simplifies the installation and operation of the dome system without any degradation of network performance. Refer to Figure 10 for pin descriptions. Figure 10.
24 VAC CONNECTIONS (OPTIONAL) If PoE is not used, the camera includes a 24 VAC power connector. Connect the power cable to the 2-pin power connector on the back of the camera using the terminal block connector (provided). Refer to Recommended Wire Gauge and Wiring Distances on page 18. The power supply connector is shown in Figure 6. Use only a Class 2 isolated power supply. Refer to Specifications on page 25 for power consumption.
CONNECTING ALARMS The Spectra Mini IP provides an alarm input for external signaling devices, such as door contacts or motion detectors. Both normally open and normally closed devices are supported. SUPERVISED ALARMS When an alarm is configured as a supervised alarm, Spectra Mini IP maintains a constant electrical current through the alarm circuit (3.3 VDC, 1 kohm). If the alarm circuit length changes, due to an electrical short or a bypass, the voltage fluctuates from its normal state.
UNSUPERVISED ALARMS When an alarm is configured as an unsupervised alarm, the dome system only triggers an alarm when the normal alarm state (normally open or normally closed) changes. Figure 15 shows the alarm and no alarm conditions of an unsupervised alarm input. A normally closed alarm input can be defeated with a bypass; a normally open input can be defeated with a cut. Figure 16 and Figure 17 show the wiring configuration for unsupervised alarm inputs.
ALARM CONNECTIONS Refer to Figure 10 on page 17 for additional wiring information. The alarm is internally connected to the Spectra Mini IP chassis. Do not connect directly to any potential except chassis ground. Figure 18.
Reset Button Use the reset button located underneath the trim ring on the mounting flange to access the following modes: Mode Function Unit Status Indicator Light Configuration Starts the reset LED selection sequence. Flashes green. Reboot Restarts the unit. Flashes green and red simultaneously when entering this mode. The LED then flashes green when mode is selected and during the reboot. Reset Resets unit to factory default settings and then restarts unit. Flashes red when entering this mode.
Troubleshooting Problem Possible Cause Suggested Remedy No video PoE power issue • Check Cat5 cable connection. • Verify PoE is enabled. • Disconnect the network cable and then reconnect it to the dome system. Check the LED on the trim ring to verify that it is flashing green, indicating the dome system has power. Power issue (24 VAC) • Check the 24 VAC power supply connection. • Disconnect the power cable and then reconnect it to the dome system.
Dome system not discovered Network not working 24 No dome system power Verify the dome system is powered correctly with PoE or with 24 VAC. Confirm power consumption with Web interface of PoE-capable switch or through blinking green LED during dome system power-up. Network conflict • Verify the dome system is physically connected to the same network as the PC running the Device Utility. • The utility will not work on a network that blocks multicast traffic.
Specifications MECHANICAL Pan Movement Vertical Tilt Manual Pan/Tilt Speeds Pan Tilt Preset Speeds Pan Tilt 360° continuous pan rotation Unobstructed +2° to -92° 0.4-80°/sec manual operation, 100°/sec turbo 0.7-40°/sec manual operation 140°/sec 80°/sec For variable speed operation an appropriate controller is required. ELECTRICAL Input Voltage/Amps Input Power PoE 18-30 VAC, 24 VAC; 0.75 A, 50/60 Hz nominal 18 VA nominal IEEE 802.
LENS Lens Zoom Zoom Speed (optical range) Horizontal Angle of View Focus Iris Control f/1.8 (focal length, 4.2~42 mm) 10X optical zoom, 8X digital zoom 1.5/2.5/4.3 seconds 46.4° wide zoom 5.0° telephoto zoom Automatic with manual override Automatic with manual override (Design and product specifications subject to change without notice.) 5.05 (12.83) Ø6.19 (15.72) 5.13 (13.03) Ø4.25 (10.80) NOTE: VALUES IN PARENTHESIS ARE CENTIMETERS; ALL OTHERS ARE INCHES.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • • • • • • • • • Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products. Three years on Spectra® IV products. Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: (800) 289-9100 Fax: (800) 289-9150 International Tel: +1 (559) 292-1981 Fax: +1 (559) 348-1120 www.pelco.