® SS20, SS22, SS2000, SS2002 Series Discreet Surveillance Enclosures Installation/ Operation Manual C429M-B (2/98) UL ® LISTED Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.
CONTENTS Section Page 1.0 GENERAL .................................................................................................. 3 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 3 2.0 DESCRIPTION .......................................................................................... 4 2.1 MODELS ............................................................................................ 4 3.0 INSTALLATION .......................................................................
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS CAUTION: This device is designed to operate at 24 volts AC power. Input voltages must not exceed 28 volts or drop below 22 volts, or else damage the the motors will occur. Should you need technical assistance, please call (800) 2899100. Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2.
2.0 DESCRIPTION Pelco’s SS20/SS22/SS2000/SS2002 Series domes are full-sphere, discreet surveillance enclosures designed to be suspended from ceilings and to compliment the interior design of businesses, hotels, and offices. The black opaque (or chrome) lower dome effectively camouflages a CTTV security/ surveillance system without compromising the quality of the video picture.
3.0 INSTALLATION Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair. 3.1 CONDUCTOR AND CABLE REQUIREMENTS NOTE: The following are cable requirements. A relay box (RB24) is available to extend the operating distance up to 13,000 feet (3,962 m) over 16 Awg wire. A minimum of 11 conductors plus coax is required, which includes common requirements for motorized zoom lens and camera AC power.
Figure 2.
Figure 3.
Figure 4.
3.2 CONNECTOR ASSEMBLY NOTE: Contacts cannot be removed from the connector without the use of an AMP extraction tool, part number ZT305183 (for 9-, 14-, or 16-pin connector) or ZT91067-2 (for 28-pin connector), which is available from Pelco. To install and test the SS2000/SS2002 Series dome you will need to assemble the connector parts provided. Fabricate the interconnecting cable as outlined below (see Figure 5): 1.
CABLE, 12 COND.
3.3 MOUNTING The SS2000/SS2002 enclosure is designed to be suspended from a suitable length of 1-1/2" pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRWA wall adapter, MRCA ceiling adapter, or coupled to a longer length of pipe. Refer to Figure 8 for mounting configurations. STRUCTURAL CEILING MOUNTING DROP CEILING MOUNTING WALL MOUNTING Figure 8.
3.4 DOME INSTALLATION To install your dome system, perform the following steps (refer to Figure 9): NOTE: The small hole in the upper dome (for safety chain attachment) should be positioned at the back (connector) end of the camera. NOTE: For SS20/SS22 mounting, refer to steps 1, 2, 6, 7, 8, and 10. For step 9, adjust the tilt and rotation, and tighten all hardware. 12 1. Select the appropriate pipe length and mounting method.
4.0 EXPLODED ASSEMBLY DIAGRAM Table A.
Figure 9.
5.0 ADJUSTMENTS To adjust the pan/tilt limits, perform the following steps. Refer to Figure 10 for limit stop locations. CAUTION: Do not attempt to adjust limit stops when the pan/tilt is in operation. Damage to the equipment can result. Do not operate equipment without limit stops. SL models are supplied without pan limit stops, therefore, no adjustments are necessary. Figure 10.
6.0 MAINTENANCE Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic. Either liquid or spray cleaner/ wax suitable for fine furniture is acceptable. Interior Surface (Except Chrome) - Clean the same as the exterior surface.
7.0 SPECIFICATIONS ELECTRICAL Input Voltage: 24 VAC required for pan/tilt Running Current Pan: Tilt: 0.31 amp (7.44 vA) 0.38 amp (9.
GENERAL Maximum Camera/ Lens Length: 12.5 inches (31.75 cm) Ambient Temperature Range: Construction Upper dome: Lower dome: Dimensions: 35°F to 120°F (1.6°C to 48.8°C) Black, high-impact plastic, ABS Acrylic hemisphere with distortion-free viewing window with light attenuation factor of 1 f-stop; model SS2002-SL has 2 fstop light attenuation factor.
NOTES Pelco Manual C429M-B (2/98) 19
8.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • Three years on Genex™ Series multiplexers. Two years on all standard motorized and fixed focal length lenses.