ADDENDUM Addendum No. C3409M Date December 22, 2005 Manuals Affected C2462M-B, C2403M-C, C2410M-H, C2491M-B, C2496M Manual Update Switch Settings for Varifocal Lens Manual Update The high resolution camera with varifocal lens and auto iris is configured at the factory for automatic exposure. SWITCH SETTINGS FOR VARIFOCAL LENS AE Functions The high resolution camera with varifocal lens and auto iris is configured at the factory for automatic exposure.
I N S T A L L A T I O N ® 090 Series Camclosure® Indoor Integrated Camera System C2462M-B (10/05)
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................... 3 WELCOME ......................................................................................................................................... 4 REMOVE THE BUBBLE ....................................................................................................................... 5 INSTALL THE BACK BOX ..........................................................
IMPORTANT SAFEGUARDS AND WARNINGS 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load.
WELCOME Thank you for purchasing Pelco’s Camclosure® Integrated Camera System for indoor applications. The ICS090 Series system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/wall. Prior to installation of your new system, thoroughly familiarize yourself with the information in this manual. The following is supplied with the 090 Series Camclosure Integrated Camera System: Qty.
REMOVE THE BUBBLE Turn the bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a non-abrasive surface. If the unit is supplied with a liner, remove the liner before installing the unit. To remove the liner, gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed. Figure 1.
INSTALL THE BACK BOX The installation methods for the ICS090 Series include the following: • • • • • Mount to the surface of a ceiling/wall Install in a suspended ceiling Install in a fixed ceiling/wall Mount to the surface of a 4S standard electrical box Install in a 4S deep electrical box Select the best method for your installation and refer to the following pages for instructions.
Installation to Surface of a Ceiling/Wall Refer to Figure 2 for the following steps. Refer to Figure 3 if installing the unit to a concrete ceiling/wall. 1. Pull video and power wires through the ceiling/wall. 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted Pair – Blue wire = Video + Gray wire = Video 3. Connect the power wires.
In-Ceiling Installation – Suspended Ceiling Refer to Figure 4 for the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a four-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box.
In-Ceiling Installation – Fixed Ceiling/Wall Refer to Figure 6 for the following steps. 1. Cut a four-inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 3. Connect the video cable/wires.
Installation to Surface of a 4S Standard Electrical Box Refer to Figure 7 for the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted Pair – Blue wire = Video + Gray wire = Video 3. Connect the power wires.
Installation in a 4S Deep Electrical Box Refer to Figure 8 for the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 3. Connect the video cable/wires.
CAMERA POSITIONING Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module. Excessively turning the module in one direction could result in damage to the wiring. Tilt 140° Pan 360° Rotation 360° Figure 9.
CAMERA ADJUSTMENTS VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS 1. Select a field of view by turning the zoom adjustment ring clockwise/counterclockwise. Refer to Figure 10. 2. Tighten the zoom locking screw. 3. Adjust the focus by moving the focus locking screw clockwise/counterclockwise. 4. Tighten the focus locking screw. Figure 10. Location of Zoom and Focus Adjustments VARIFOCAL LENS AUTO IRIS LEVEL ADJUSTMENT To adjust the auto iris level do the following: 1.
SWITCH SETTINGS Switch Settings for Fixed Focal Length Lens Without Auto Iris Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots.
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. To eliminate vertical roll reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If reversing the connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the cameras to one another.
REINSTALL THE DOME DOME LINER INSTALLATION If the unit is supplied with a dome liner, reinstall the liner before installing the bubble. To install the liner refer to Figure 13 and do the following: 1. Align the studs located on the camera module with the clips on the liner. 2. Lightly pinch the sides of the liner, opposite from the clips, and place clips over the studs. 3. Once the liner is secure, position the viewing window of the liner over the lens of the camera. 4. Install the bubble. Figure 13.
SERVICE CONNECTOR An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable simply plug one end of the cable directly into the service connector of the ICS090 and connect the other end to any standard BNC (VIDEO IN) connector on a monitor. To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store: 1 1 1 2.
SPECIFICATIONS BACKBOX Electrical Input Voltage: Power Consumption: Video Connector: 12 VDC or 24 VAC (±10%), auto-sensing 3 watts or less BNC General Pan/Tilt Adjustment Pan: Tilt: Rotation: Construction Back Box and Surface Mount Ring: Bubble: Finish: Environment: Operating Temperature: Weight Unit: Shipping: 360° 140° (20° to 160° range) 360° ABS plastic Polycarbonate White Indoor 32°F to 120°F (0° to 49°C) .52 lb (.24 kg) 2 lb (.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
® World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.