® PSKIT8100 Pressure Sensor Option For EH8100 Series Pressurized Camera Enclosure C1445M-D (11/04)
Contents Important Safeguards and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safeguards and Warnings 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 6.
Installation ENCLOSURE DISASSEMBLY 1. Disconnect power to the enclosure. 2. Remove the ground wire from the ground stud on the back of the enclosure. 3. Remove the electrical connector from the rear of the enclosure by turning the outer ring counterclockwise and pulling the mating portion of the connector off. 4. You may remove the enclosure from its mount to make the installation process easier. 5. Remove the cap from the Schraeder valve (refer to Figure 1). 6.
Pressure Sensor Installation To install the pressure sensor, perform the following steps. 1. Remove the screw located inside the top portion of the enclosure’s rear plate (refer to Figure 2). Insert the pressure sensor tube fitting in the hole. 2. Loosen the camera sled mounting screws (refer to Figure 2). Slide the sensor bracket under the mounting screws and ground lug. Tighten the screws. 3. Connect the wire leads (refer to Figure 2 and Figure 3): a.
PRESSURE SENSOR SWITCH AC LINE AC NEUT HTR GREEN/WHITE WIRE WHITE/GREEN WIRE GROUND HTR THERMOSTAT A B C L K M N S P D E J R F PP ZOOM G PP FOCUS PP COM IRIS COLOR COAX CORE COAX SHIELD BLK/WHT RED/WHT BLU VIO GRN/WHT BLK WHT/GRN BRN RED ORG COM YEL WHT YEL/WHT GRY/WHT FOCUS TABLE A FUNCTION VIDEO VIDEO PP +5V PP COM CAMERA AC LINE CAMERA AC NEUT PS SWITCH AC LINE PS SWITCH IRIS FOCUS ZOOM LENS AC NEUTRAL PP FOCUS PP ZOOM ZOOM PIN NO.
Enclosure Reassembly and Recharging REASSEMBLY Whenever the enclosure is disassembled, it should be recharged after reassembly and prior to installation. Recharging requires the use of a Pelco EH8000RKIT recharge kit (or equivalent) and applicable O-ring kit, part EH8004ORKIT or EH8006ORKIT. To prepare the enclosure for recharging, follow the steps below. 1. Once the enclosure has been disassembled, remove the O-ring from the rear plate and install a new O-ring in the O-ring groove. 2.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products and the following fixed camera models: CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and CC3651H-2X.
® Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.