24 VAC Wiring Distances
Power consumption for the environmental version is 82 VA. Use a 24 VAC transformer with a minimum of 100 VA per dome.
NOTE: Wire distances are based on normal condition estimates. The actual voltage drop can vary depending on the condition of the wire,
conductor being used, temperature, and connections.
Camera Configuration Sequence
Once the camera is installed and power is applied, the camera undergoes a configuration sequence, taking approximately two minutes
to complete. The camera will come online once the configuration sequence is complete.
NOTE: If the camera connected to a network without a DHCP server and DHCP is enabled, the configuration sequence can take up to five
minutes to complete.
Table A: 24 VAC Wiring Distances
AC/DC Total VA
Wire Gauge
20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2) 14 AWG (2.5 mm2)
23 VA 38 m (123 ft) 60 m (196 ft) 95 m (311 ft) 151 m (495 ft)
82 VA 11 m (36 ft) 17 m (56 ft) 27 m (89 ft) 43 m (141 ft)