Operation Manual

32
1. Select Handlers from the Events menu.
2. Click New Handler or select the handler you want to reconfigure.
3. Provide a name, between 2 and 23 alphanumeric characters, for the event handler in the Name box.
4. Select the “Go to Preset” handler Type.
5. Select a preset from the Preset drop-down menu.
6. (Optional) Set time filters to determine the days and times during which the handler will be active. If you do not select any filters,
the handler will remain active at all times. All time values must be formatted in 24-hour notation.
7. (Optional) If available, select the source(s) that you want to trigger this event handler.
8. Click Submit.
Configuring an Event Handler: Open/Close Relay
Some models require the Pelco Alarm accessory be connected to the camera’s accessory port for Open/Close Relay to function.
The Open/Close handler opens or closes a relay when a source event occurs.
1. Select Handlers from the Events menu.
2. Click New Handler or select the handler you want to reconfigure.
3. Provide a name, between 2 and 23 alphanumeric characters, for the event handler in the Name box.
4. Select the Open/Close Relay handler Type.
5. Select your relay bank. Relay bank options might include GPIO PCP (General Purpose Input/Output) or the serial number of your relay
device; relay bank options might change depending on your model or accessories attached to your camera.
6. Select the individual relay you want to trigger when an event occurs from the Relay drop-down menu.
7. Use the On Time controls to set the amount of time the relay will remain open, up to 200 seconds.
8. Use the Off Time controls to set the amount of time the relay will remain closed, up to 200 seconds.
9. Set the pulse count for the relay. The pulse count is the number of relay pulses (number of on and off cycles).
10. (Optional) Set time filters to determine the days and times during which the handler will be active. If you do not select any filters,
the handler will remain active at all times. All time values must be formatted in 24-hour notation.
11. (Optional) If available, select the source(s) that you want to trigger this event handler.
12. Click Submit.
Configuring an Event Handler: Run Tour
You must define a preset tour before you can create a Run Tour event handler.
1. Place your mouse pointer over the Events tab.
2. Click New Handler or select the handler you want to reconfigure.
3. Select Handlers from the drop-down menu.
4. In the New Event Handler section of the window, click the Name box and type a user-friendly name (2 to 23 alphanumeric charac-
ters).
5. Select Run Tour from the Type drop-down menu.